Three-dimensional custom-designed cementless femoral stem for osteoarthritis secondary to congenital dislocation of the hip.
نویسندگان
چکیده
A clinical and radiological study was conducted on 97 total hip replacements performed for congenital hip dislocation in 79 patients between 1989 and 1998 using a three-dimensional custom-made cementless stem. The mean age at operation was 48 years (17 to 72) and the mean follow-up was for 123 months (83 to 182). According to the Crowe classification, there were 37 class I, 28 class II, 13 class III and 19 class IV hips. The mean leg lengthening was 25 mm (5 to 58), the mean pre-operative femoral anteversion was 38.6 degrees (2 degrees to 86 degrees ) and the mean correction in the prosthetic neck was -23.6 degrees (-71 degrees to 13 degrees ). The mean Harris hip score improved from 58 (15 to 84) to 93 (40 to 100) points. A revision was required in six hips (6.2%). The overall survival rate was 89.5% (95% confidence interval 89.2 to 89.8) at 13 years when two hips were at risk. This custom-made cementless femoral component, which can be accommodated in the abnormal proximal femur and will correct the anteversion and frontal offset, provided good results without recourse to proximal femoral corrective osteotomy.
منابع مشابه
Total Hip Arthroplasty with Modular Stem for Dysplastic Hips in South Asian Population
Introduction: Optimum component positioning and orientation is required to optimize the functional result during total hip arthroplasty for dysplastic hips. Patients and methods: Sixty-two patients (66 hips) including 33 males and 29 females underwent total hip arthroplasty using modular stem prosthesis at an average age of 40.6 years (range 17 to 49 years). Nineteen hips were clas...
متن کاملCementless Total Hip Arthroplasty After an Iatrogenic Subtrochanteric Fracture due to Hardware Removal: A Case Report
Introduction: Total hip arthroplasty (THA) after proximal femoral fixation is a challenging procedure due to possible hardware-related complications. Case presentation: A 78-year-old female with hip osteoarthritis had a proximal femoral osteotomy fixed using a blade plate in the same femur 41 years ago. A two-step approach was planned. After a challenging...
متن کاملLong-Term Results of Cementless Total Hip Arthroplasty Using a Modular Stem in Patients with Femoral Head Osteonecrosis
Cementless modular stemwas designed to allow the surgeon to independently match the anatomy of the metaphyseal and diaphyseal regions of the femoral canal of an individual patient.1 S-ROM stem (DePuy/Johnson & Johnson), which has a hollow proximal sleeve and separate cylindrical core, was introduced in 1984. So far, long-term results of this prosthesis have been excellent in osteoarthritis, dev...
متن کاملMedium-term Outcomes of Cemented Prostheses and Cementless Modular Prostheses in Revision Total Hip Arthroplasty
There is an increasing trend towards cementless modular femoral prostheses for revision hip replacement surgery, especially in patients with severe proximal femoral bone defects. However, for minor femoral bone defects, the benefit of cementless modular is not clear. We designed a retrospective cross-sectional study to compare outcomes of the two femoral implant designs. There were no significa...
متن کاملThe modern, hybrid total hip arthroplasty for primary osteoarthritis at the Hospital for Special Surgery.
We describe our technique and rationale using hybrid fixation for primary total hip arthroplasty (THA) at the Hospital for Special Surgery. Modern uncemented acetabular components have few screw holes, or no holes, polished inner surfaces, improved locking mechanisms, and maximised thickness and shell-liner conformity. Uncemented sockets can be combined with highly cross-linked polyethylene lin...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Journal of bone and joint surgery. British volume
دوره 89 12 شماره
صفحات -
تاریخ انتشار 2007