Computational Methodology for Absolute Calibration Curves for Microfluidic Optical Analyses

نویسندگان

  • Chia-pin Chang
  • David J. Nagel
  • Mona E. Zaghloul
چکیده

Optical fluorescence and absorption are two of the primary techniques used for analytical microfluidics. We provide a thorough yet tractable method for computing the performance of diverse optical micro-analytical systems. Sample sizes range from nano- to many micro-liters and concentrations from nano- to milli-molar. Equations are provided to trace quantitatively the flow of the fundamental entities, namely photons and electrons, and the conversion of energy from the source, through optical components, samples and spectral-selective components, to the detectors and beyond. The equations permit facile computations of calibration curves that relate the concentrations or numbers of molecules measured to the absolute signals from the system. This methodology provides the basis for both detailed understanding and improved design of microfluidic optical analytical systems. It saves prototype turn-around time, and is much simpler and faster to use than ray tracing programs. Over two thousand spreadsheet computations were performed during this study. We found that some design variations produce higher signal levels and, for constant noise levels, lower minimum detection limits. Improvements of more than a factor of 1,000 were realized.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A kinetic-based sigmoidal model for the polymerase chain reaction and its application to high-capacity absolute quantitative real-time PCR

BACKGROUND Based upon defining a common reference point, current real-time quantitative PCR technologies compare relative differences in amplification profile position. As such, absolute quantification requires construction of target-specific standard curves that are highly resource intensive and prone to introducing quantitative errors. Sigmoidal modeling using nonlinear regression has previou...

متن کامل

0 v 2 5 M ay 2 00 3 Spectral Irradiance Calibration in the Infrared . XIV : the Absolute Calibration of 2 MASS

Element-by-element we have combined the optical components in the three 2MASS cameras, and incorporated detector quantum efficiency curves and site-specific atmospheric transmissions, to create three relative spectral response curves (RSRs). We provide the absolute 2MASS attributes associated with " zero magnitude " in the JHK s bands so that these RSRs may be used for synthetic photometry. The...

متن کامل

X iv : a st ro - p h / 03 04 35 0 v 1 1 8 A pr 2 00 3 Spectral Irradiance Calibration in the Infrared . XIV : the Absolute Calibration of 2 MASS

Received ; accepted – 2 – ABSTRACT Element-by-element we have combined the optical components in the three 2MASS cameras, and incorporated detector quantum efficiency curves and site-specific atmospheric transmissions, to create three relative spectral response curves (RSRs). We provide the absolute 2MASS attributes associated with " zero magnitude " in the JHK s bands so that these RSRs may be...

متن کامل

Amperometric quantification based on serial dilution microfluidic systems.

This paper describes a microfluidic device fabricated in poly(dimethylsiloxane) that was employed to perform amperometric quantifications using on-chip calibration curves and on-chip standard addition methods. This device integrated a network of Au electrodes within a microfluidic structure designed for automatic preparation of a series of solutions containing an electroactive molecule at a con...

متن کامل

Fusion Framework for Emotional Electrocardiogram and Galvanic Skin Response Recognition: Applying Wavelet Transform

Introduction To extract and combine information from different modalities, fusion techniques are commonly applied to promote system performance. In this study, we aimed to examine the effectiveness of fusion techniques in emotion recognition. Materials and Methods Electrocardiogram (ECG) and galvanic skin responses (GSR) of 11 healthy female students (mean age: 22.73±1.68 years) were collected ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2010