The immediately loaded single implant-retained mandibular overdenture: a 36-month prospective study.
نویسندگان
چکیده
PURPOSE The aim of this study was to ascertain whether simplifying mandibular overdenture treatment by using single-stage surgery and immediate prosthetic loading of a single implant will achieve acceptable implant success rates, functional improvement, and increased patient satisfaction. As part of this study, the Mk III Branemark implant with an oxidized surface was compared to the classic machined Mk III Branemark implant. MATERIALS AND METHODS Thirty-five patients (mean age: 68 years) with problematic mandibular dentures were treated. The primary complaints among the patients referred to the clinic for treatment were poor retention of the mandibular denture, instability, denture sores, and phonetic problems. Initially, patients were placed randomly into the "machined surface" or "oxidized surface" groups. A single implant was placed in the mandibular midline with high initial stability. A ball attachment was placed and the retentive cap incorporated into the existing denture. Reviews took place at 3, 12, and 36 months posttreatment. Clinical assessments, radiographs made with custom film holders, and stability measurements by both manual and resonance frequency analysis methods were recorded. All complications, failures, maintenance, and reasons for dropout were noted. Visual analog scale questionnaires were used to record patient satisfaction (analysis of variance: P < .05). RESULTS Three of eight machined-surface implants failed, representing an unacceptably high failure rate (37.5%). The machined surface was therefore discontinued for this study. One machined and two oxidized-surface implants did not achieve sufficient primary stability to be immediately loaded, so they were treated with a two-stage delayed loading protocol. The 25 immediately loaded oxidized-surface implants were all classified as surviving at the 36-month recall. Patient satisfaction was very high with a significant increase in all comfort and functional parameters. CONCLUSIONS Within the limitations of this study and research design, it appears that over a 3-year observation period, the immediately loaded single implant-retained mandibular overdenture, using an oxidized-surface implant and the existing prosthesis in a small group of prosthetically maladaptive patients, can provide a beneficial treatment outcome with a minimal financial outlay. Int J Prosthodont 2010;23:13-21.
منابع مشابه
Implant-retained mandibular overdentures with immediate loading: a prospective study of ITI implants.
A prospective study was conducted in which 21 patients received a mandibular implant-supported overdenture. Eighty-four ITI screw-type implants were placed in the interforaminal area of the mental symphysis (4 implants per patient). Immediately after implant placement, a U-shaped gold or titanium bar was fabricated and implants were loaded with an implant-retained overdenture. Of 21 patients tr...
متن کاملEarly Loaded Single Implant Reinforced Mandibular Overdenture
Rehabilitating atrophied mandible with two-implant supported denture is a common treatment modality for implant retained removable overdenture in mandible. This paper aims to design a treatment modality where single implant reinforced overdenture is fabricated for a severely atrophied mandibular ridge with early loading protocol. Results of studies have shown that a single implant mandibular ov...
متن کاملA Prospective Study of Early Loaded Single Implant-Retained Mandibular Overdentures: Preliminary One-Year Results
Purpose. To investigate the predictability of simplifying mandibular overdenture treatment using one-stage surgery and early prosthetic loading of a single implant. Materials and Methods. Twenty edentulous patients with problematic existing mandibular dentures were treated. A single implant with a chemically modified surface (SLActive, Straumann AG, Basel, Switzerland) was placed into the mandi...
متن کاملSingle Versus Two Dental Implant Retained Mandibular Overdenture: Study Protocol for a Randomized Controlled Trial
Background: The consensus is that the standard treatment of choice for the edentulous mandible should be a two implant retained mandibular overdenture. Some clinicians have tried single median implant to retain the mandibular overdenture, however, there is lack of scientific information with single implant retained mandibular overdenture. Therefore the purpose of the current randomized clinical...
متن کاملImmediate loading implants with mandibular overdenture: a 48-month prospective follow-up study.
The aim of this prospective clinical study was to evaluate patient rehabilitation with two immediately loaded implants and bar-retained mandibular overdentures after 48 months of follow-up. Twenty patients were treated with two implants each; of these, 17 patients were re-evaluated for comparison. Gender, age, plaque index, gingival inflammation, keratinized mucosa, probing depth, bleeding, and...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The International journal of prosthodontics
دوره 23 1 شماره
صفحات -
تاریخ انتشار 2010