Comparison of Gen-probe transcription-mediated amplification, Abbott PCR, and Roche PCR assays for detection of wild-type and mutant plasmid strains of Chlamydia trachomatis in Sweden.
نویسندگان
چکیده
The clinical performance of two nucleic acid amplification assays targeting the cryptic plasmid and two assays targeting rRNA molecules in Chlamydia trachomatis was examined. First-catch urine samples from Malmoe, Sweden, were tested for C. trachomatis with the Abbott real-time PCR assay m2000 and an in-house PCR for the new variant strain of C. trachomatis with a deletion in the cryptic plasmid. Aliquots of the urine samples were sent to Aarhus, Denmark, and further examined with the Roche COBAS Amplicor CT (RCA) PCR, the Gen-Probe Aptima Combo 2 assay (AC2) targeting the C. trachomatis 23S rRNA, and the Aptima C. trachomatis assay (ACT) targeting the 16S rRNA molecule. A positive prevalence of 9% (163/1,808 urine samples examined) was detected according to the combined reference standard. The clinical sensitivity and specificity of the four assays were as follows: for ACT, 100% (163/163) and 99.9% (1,643/1,645), respectively; for AC2, 100% (163/163) and 99.6% (1,640/1,645); for m2000, 68.7% (112/163) and 99.9% (1,644/1,645); for RCA, 63.8% (104/163) and 99.9% (1,643/1,645). The two Gen-Probe assays detected all mutant strains characterized by the in-house PCR as having the deletion in the cryptic plasmid, whereas the Roche and the Abbott PCRs targeting the plasmid were both unable to detect the plasmid mutant. The difference in clinical sensitivity between the plasmid PCR assays m2000 and RCA, on the one hand, and the rRNA assays AC2 and ACT, on the other, could be attributed almost exclusively to the presence of the plasmid mutant in about one-quarter of the Chlamydia-positive samples examined.
منابع مشابه
Comparison of the Abbott RealTime CT new formulation assay with two other commercial assays for detection of wild-type and new variant strains of Chlamydia trachomatis.
In an analytical-method comparison study of clinical samples, the Abbott RealTime CT new formulation assay (m2000 real-time PCR), consisting of a duplex PCR targeting different parts of the cryptic plasmid in Chlamydia trachomatis, was compared both with version 2 of the Roche Cobas TaqMan CT assay, comprising a duplex PCR for a target in the cryptic plasmid and the omp1 gene, and with the Gen-...
متن کاملComparison of three commercially available amplification assays, AMP CT, LCx, and COBAS AMPLICOR, for detection of Chlamydia trachomatis in first-void urine.
We compared the Gen-Probe transcription-mediated amplification assay (AMP CT), the Abbott LCx assay, and the Roche COBAS AMPLICOR assay for the detection of Chlamydia trachomatis in a mixed population in urine samples. First-void urine, urethral specimens, and cervical specimens in females were obtained from 1,000 patients (544 males and 456 females) visiting the outpatient sexually transmitted...
متن کاملDetection of Chlamydia trachomatis in genital swabs: comparison of commercial and in house amplification methods with culture.
AIMS To evaluate the sensitivity of the Roche Cobas, Roche Amplicor plate kit, ligase chain reaction (LCR), and an in house polymerase chain reaction (PCR) by titration of purified elementary bodies (EB) and also to test 245 urethral and endocervical specimens for Chlamydia trachomatis by the four assays as well as conventional culture. STUDY DESIGN EB titrations were run in duplicate in each...
متن کاملExternal quality assessment program for Chlamydia trachomatis diagnostic testing by nucleic acid amplification assays.
We report the results from 57 Australian diagnostic laboratories testing two external quality assessment panels using either the Roche Amplicor Chlamydia trachomatis test (R-PCR) or the Abbott LCx Chlamydia trachomatis assay (A-ligase chain reaction [LCR]). Panel samples were either normal urine spiked with Chlamydia trachomatis antigen or clinical urine specimens. There was no significant diff...
متن کاملComparison between the Gen-Probe transcription-mediated amplification Trichomonas vaginalis research assay and real-time PCR for Trichomonas vaginalis detection using a Roche LightCycler instrument with female self-obtained vaginal swab samples and male urine samples.
This study compared two assays for Trichomonas vaginalis detection, Gen-Probe's transcription-mediated amplification (TMA) assay for Trichomonas vaginalis and BTUB FRET PCR, using self-obtained clinical samples from 611 patients. Infection status was defined as two positive results by two different tests. The initial TMA assay sensitivity was 96.7%; specificity was 97.5%. The TMA assay was comp...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of clinical microbiology
دوره 46 12 شماره
صفحات -
تاریخ انتشار 2008