Self-Gated Cine MRI for Clinical Wall Motion Abnormality Studies

نویسندگان

  • P. Chalasani
  • D. N. Sandman
  • M. Crowe
  • O. P. Simonetti
  • E. Wu
  • J. Carr
  • A. Larson
چکیده

P. Chalasani, D. N. Sandman, M. Crowe, O. P. Simonetti, E. Wu, J. Carr, A. Larson Advocate Illinois Masonic Medical Center, Chicago, Illinois, United States, Northwestern University, Chicago, Illinois, United States, Ohio State University, Columbus, Ohio, United States Introduction: Electrocardiogram (ECG)-gating uses an R-wave trigger to synchronize segmented cine data acquisition to the cardiac cycle. Disadvantages of ECG-gating are additional patient preparation time, susceptibility to RF and magnetic interference, and is ineffective in a significant percentage of patients. More recently, self-gating techniques have been described which potentially eliminate the need for external physiological signal monitoring. Self-gated cine has recently shown to provide equivalent image quality to ECG gated cine in a limited sample of healthy volunteers and patients. However, the self-gating synchronization signal is largely dependent upon cardiac tissue motion and blood flow and therefore further clinical validation of the self-gating technique in wall motion abnormality studies was necessary. The purpose of this study was to demonstrate the clinical effectiveness of using self-gated cine sequence for qualitative wall motion abnormality assessments. Methods: The self-gated sequence is a modified retrospectively gated TrueFISP cine sequence that acquires a short second echo after readout. The peak amplitude of the second echo varies in proportion to the average signal in the image, which is expected to change in synchrony with the cardiac cycle due to heart motion as well as through plane blood flow. An automated peak-detection algorithm is used to determine the trigger times. Indications for cardiac MR were variable but primarily included patients undergoing myocardial viability and perfusion studies. Imaging was performed using a 1.5T Magnetom Avanto scanner (Siemens, Erlangen, Germany) with a 12-element body array coil. Breath-held acquisitions were performed using the following parameters: TR/TE = 3.4/1.6 ms, 350x263mm FOV, 256x135 matrix, 60 ms temporal resolution, 6 mm slice thickness, 1.0 kHz/pixel BW. Multiple slices, including short and long-axis views, were obtained in 19 patients for a total of 50 measurements. ECG and self-gated image series were retrospectively reconstructed from each measurement, resulting in 100 total image series. For each image series, segmental wall motion was scored using the 16 segment model of the American Society of Echocardiography. All 100 series were evaluated for wall motion (0-normal, 1-mild/moderate hypokinesia, 2-severe hypokinesia, 3-akinesia, 4-dyskinesia) and wall thickness (0-normal, 1-thinned) by an independent, blinded reviewer. ECG and self-gated data was compared using a two-tailed t-test with statistical significance set at α=0.05 level. Results: Quantitative results showed that there was no statistically significant difference between cardiac wall motion and wall thickness scores between ECG-gated and self-gated acquisition (Table 1). The standard deviations were increased due to two images series whose difference between ECG and self gated score for mean wall motion and thickness was high (difference between wall motion 11, 18, thickness3). Qualitative analysis showed no statistical difference between image quality by both gating techniques (p=0.05). Conclusion: The self-gated cine TrueFISP sequence, using a conventional Cartesian sampling scheme, showed no difference from ECG-gated sequences in quantifying wall motion and thickness in a sample of patients referred for clinical cardiac MR. This promising self-gating technique has many advantages to ECG-gating and will continue to be evaluated in a larger population of patients. Table 1: Results of data analysis

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Nonlinear profile order for 3D hybrid radial acquisition applied to self-gated free-breathing cardiac cine MRI

Background Self-gated free-breathing 3D cardiac cine MRI has been widely introduced, which provides similar image quality and functional measurements as breath-hold technique [1-3]. In self-gated free-breathing cardiac cine MRI, respiratory and cardiac motions are unpredictable during the acquisition especially in retrospective reconstruction. Therefore, nonuniform k-space distribution is a maj...

متن کامل

Self-Gated CINE MRI for Combined Contrast-Enhanced Imaging and Wall-Stiffness Measurements of Murine Aortic Atherosclerotic Lesions

BACKGROUND High-resolution contrast-enhanced imaging of the murine atherosclerotic vessel wall is difficult due to unpredictable flow artifacts, motion of the thin artery wall and problems with flow suppression in the presence of a circulating contrast agent. METHODS AND RESULTS We applied a 2D-FLASH retrospective-gated CINE MRI method at 9.4T to characterize atherosclerotic plaques and vesse...

متن کامل

Evaluation of left ventricular wall motion, volumes, and ejection fraction by gated myocardial tomography with technetium 99m-labeled tetrofosmin: a comparison with cine magnetic resonance imaging.

BACKGROUND Whether left ventricular function can be assessed accurately by gated single photon emission computed tomography (SPECT) in patients with myocardial infarction and severe perfusion defects is not well known. METHODS AND RESULTS Twenty-five patients with an acute myocardial infarction underwent 99mTc-labeled tetrofosmin (99mTc-tetrofosmin) gated SPECT and cine magnetic resonance ima...

متن کامل

High-quality reconstruction of arrhythmic cardiac cycles

Background The current clinical standard in cardiac functional MRI is retrospectively gated cine MRI. The technique is relying on a regular heart beat and cardiac cycles showing substantial deviation from the mean heart rate are excluded, often causing reduced image quality and completely suppressing arrhythmic cycles. We introduce a new correlation based self-gating approach enabling reconstru...

متن کامل

Quantifying right ventricular motion and strain using 3D cine DENSE MRI

Background The RV is difficult to image because of its thin wall, asymmetric geometry and complex motion. DENSE is a quantitative MRI technique for measuring myocardial displacement and strain at high spatial and temporal resolutions [1,2]. DENSE encodes tissue displacement directly into the image phase, allowing for the direct extraction of motion data at a pixel resolution. A free-breathing n...

متن کامل