A novel method to obtain proximal plethysmographic information from distal measurements using the impedance plethysmogram

نویسندگان

  • J. Gomez-Clapers
  • R. Casanella
چکیده

We present a novel method to detect proximal volume changes based on the impedance plethysmogram (IPG) measured from limb to limb with two electrode pairs symmetrically placed at distal areas of the upper or the lower limbs. Since the measurement is sensitive to changes along the whole current path, this method allows us to detect changes in arteries that are more proximal to the torso than the measurement sites. Our results show that the Pulse Arrival Time (PAT) measured from the R peak of the ECG to the hand-to-hand IPG is close to the PAT to the elbow whereas the PAT measured from the R peak of the ECG to the foot-to-foot IPG is close to the PAT to the knee. This opens new avenues for noninvasive cardiovascular measurements based only on electrodes in contact with hands or feet.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Anthropometric Measurements of Distal Femur to Design the Femoral Component of Total Knee Arthroplasty for the Iranian Population

Background: Acquiring knowledge about anatomic and geometric quantities of bones is among the most vitalparameters in orthopedic surgery that has a significant effect on the treatment of various disorders and subsequentoutcomes. The aim of this study was to obtain anthropometric information for distal femur in order to compare withsimilar dimensions of prosthesis used in total...

متن کامل

Review Article: Application of Electrical Impedance Spectroscopy in Bladder Cancer Screening

Introduction Bladder cancer is the most common malignancy in elderly people and most bladder cancers are transitional cell carcinomas (TCC). Bladder pathology is usually investigated visually by cystoscopy and this technique can represent different conditions ranging from simple inflammation to flat CIS. However, biopsies must be taken from the suspected area to obtain diagnostic information. T...

متن کامل

Variable Impedance Control for Rehabilitation Robot using Interval Type-2 Fuzzy Logic

In this study, a novel variable impedance control for a lower-limb rehabilitation robotic system using voltage control strategy is presented. The majority of existing control approaches are based on control torque strategy, which require the knowledge of robot dynamics as well as dynamic of patients. This requires the controller to overcome complex problems such as uncertainties and nonlinearit...

متن کامل

A Novel Method for Impedance Calculation of Distance Relays Using Third Order Interpolation

All algorithms for impedance calculation use an analog-to-digital converter. The high accuracy of the impedance seen by a distance relay is an important factor in the correct isolation of the faulty part of power systems. To achieve this, a novel&#10technique based on third order interpolation is used in this paper. According to this technique, the times and the values of the obtained samples a...

متن کامل

A Novel Method for Impedance Calculation of Distance Relays Using Third Order Interpolation

All algorithms for impedance calculation use an analog-to-digital converter. The high accuracy of the impedance seen by a distance relay is an important factor in the correct isolation of the faulty part of power systems. To achieve this, a novel technique based on third order interpolation is used in this paper. According to this technique, the times and the values of the obtained samples are...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015