Non-uniform diffusion encoding directions schemes to minimize fiber direction uncertainty in skeletal muscle DTI

نویسندگان

  • D. C. Karampinos
  • C. P. Hess
  • K. Arfanakis
  • S. Banerjee
  • E. T. Han
  • T. M. Link
  • S. Majumdar
چکیده

Introduction: Recent studies employing diffusion MRI to characterize skeletal muscle and perform muscle fiber tractography have shown the need to minimize fiber directional uncertainty [1]. Dominated by the inherently low SNR of muscle diffusion MRI and the low anisotropy of muscle fibers, Monte Carlo studies suggest that tensor orientation estimates may vary up to 10% in a typical DTI experiment [2]. In the brain, it has previously been demonstrated that directional uncertainty also depends upon the magnitude of diffusion weighting and the distribution of directional measurements [3]. When the dominant orientation of white matter is known a priori, it is possible to further reduce the uncertainty of different metrics of the diffusion tensor (trace, fractional anisotropy or primary eigenvector orientation) through non-uniform distribution of diffusion encodings [4-7]. Specifically, diffusion encoding schemes using directions in an angular band around the fiber orientation can minimize the direction uncertainty [5]. In this work, we propose a novel approach for increasing the precision of tensor directional estimates in skeletal muscle, for which a dominant fiber orientation is characteristic in the extremities (Fig. 1a). Results from computer simulations and preliminary in vivo experiments are presented, showing that fiber directional uncertainty can be reduced by up to 37%, which might have implications in improving the precision of DTI-based skeletal muscle biomechanical models. Materials and Methods: We used an analytical formulation for distributing points on a hemisphere together with a recently developed framework for error propagation in DTI [9,10] to minimize the mean area of the elliptical cone of uncertainty (COU). Simulations and calculation of optimized directions was performed using MATLAB. A uniform distribution of directional measurements of diffusion Ξ was first at 30 non-collinear points on the hemisphere using a 3D spiral trajectory [8] (Fig. 1b). A compression transform T is then defined so that the directions are limited to an angular band between two zenith angles, parameterized by the tilt angle of the band θo and the thickness of the band Δθ. The optimal transformation is defined as the one that minimizes the area of COU [9,10], as constrained by an assumed dominant orientation and dispersion around this orientation. The opimized non uniform diffusion encoding scheme is defined by applying the transformation T on Ξ to derive the optimized scheme Ξ’=T(Ξ) (Fig 1c). Simulations: Muscle fibers were assumed to have zenith angle following a Rayleigh distribution with parameter=10o and azimuth angle following a uniform distribution, resulting in a population of fibers within a cone around the Z axis. Simulated tensor parameters were λ1/λ2/λ3= 2.0/1.4/1.2 10 m/s and SNR=60 for the b=0 signal, corresponding to a typical in vivo experiment [2]. In vivo measurements: An eight-channel lower extremity coil was used to scan the left calf muscle of one healthy volunteer on a 3 T full-body GE scanner. Diffusion-weighted images were acquired using a single-shot diffusion-weighted stimulatedecho EPI sequence [11] with the following parameters: TR/TE=2000/52 ms, FOV=20x20 cm, slice thickness=10 mm, acquisition matrix=64x40 (5/8 partial phase encoding), Nex=10, 6 slices, δ=15 ms, Δ=40 ms, g=3 G/cm, b=541 s/mm. The acquisition was repeated twice: once with the standard uniform diffusion encoding scheme Ξ and once with the optimized nonuniform diffusion encoding scheme Ξ’. Results: Simulations: Fig 1c. shows the optimized 30-directions scheme (θo=44o, Δθ=57o). Simulations are also performed for the two schemes to compute the elliptical cone of uncertainty as a function of the angle θ1 between the fiber and the Z axis. The optimized scheme results in a decrease in the area of the COU up to 37% (Fig. 2a). Figs. 2b and 2c show the effect of the directions scheme on the major and minor axes of the elliptical COU. In vivo results: Bootstrap resampling is performed for the signal in an ROI of the tibialis anterior (TA) muscle (Fg. 3a). 200 samples are formed from the 30-directions data (with 5 acquisitions averaged). The cone of uncertainty is constructed based on the projection of the primary eigenvector of the bootstap samples on the plane defined by the mean secondary and tertiary eigenvectors (Figs. 3b and 3c) [12]. The optimized directions scheme leads to a decrease in the area of the ellipltical COU by 12%. Discussion and Conclusion: The present optimization framework uses analytical error propagation formulas instead of Monte Carlo simulations to accelerate the formation of optimized diffusion directions schemes. The presented examination the COU with the optimized scheme in the in vivo data did nor take into account the effect of other sources of noise, other than thermal noise, such as motion. The analyis of the in vivo data also focused on the TA muscle, which is known to have a low pennation angle (around 10o). Therefore, further work would be required towards establishing diffusion schemes with improved noise properties for multiple muscle groups and undestanding the effect of the optimized schemes in the diffusion anisotropy metrics. However, the present preliminary results show that optimized diffusion directions schemes can minimize the cone of uncertainty in DTI of skeletal muscles with a priori known preferential orientation. References: [1] Heemskerk et al, MRM 61: 467-472, 2009, [2] Damon et al, MRM 60: 934-944, 2008, [3] Jones et al, MRM 515-525, 1999, [4] Peng et al, MRI 25: 147-153, 2007, [5] Yanasak et al, MICCAI 2008, p. 866-873, [6] Gao et al, Neuroimage 44: 729-741, 2009, [7] Majumdar et al, ISMRM 2009, p. 3513, [8] Wong et al, MRM 32: 778-784, 1994, [9] Koay et al, IEEE TMI 26: 1017-1034, 2007, [10] Koay et al, IEEE TMI 27: 834-846, 2008, [11] Karampinos et al, ABME in press, [12] Jeong et al, MRM 60: 1408-1421, 2008. Fig. 1: (a) Histogram of the zenith angle of the primary eigenvector from a calf muscle DTI dataset (64x64 matrix, 6 slices), and (b-c) 30 diffusion encoding directions schemes: (b) standard uniform scheme Ξ, and (c) optimized non-uniform scheme Ξ’.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diffusion tensor encoding schemes optimized for white matter fibers with selected orientations.

A method to produce gradient encoding schemes that minimize the noise of diffusion tensor imaging (DTI) indices for selected fiber orientations has been developed. The accuracy of DTI measurements depends on the gradient encoding scheme used. Most current acquisition schemes contain diffusion directions uniformly distributed in 3D space in order to provide equal noise levels for fibers in any o...

متن کامل

Evidence of 3-D Fabric Structure in Skeletal Muscle via in-Vivo DTI and Eigenspace Reconstruction

Introduction: The established difference between the secondary and tertiary eigenvalues of the diffusion tensor in skeletal muscle [1] hints of the presence of anisotropic diffusion in the transverse direction (i.e. normal to the local fiber). DTI MRI has been employed successfully to reconstruct the fiber tracts in the human tibialis anterior [2], and its potential to elucidate additional stru...

متن کامل

Diffusion tensor imaging in biomechanical studies of skeletal muscle function.

In numerical simulations of skeletal muscle contractions, geometric information is of major importance. The aim of the present study was to determine whether the diffusion tensor imaging (DTI) technique is suitable to obtain valid input with regard to skeletal muscle fibre direction. The accuracy of the DTI method was therefore studied by comparison of DTI fibre directions in the rat tibialis a...

متن کامل

Determination of Fiber Direction in High Angular Resolution Diffusion Images using Spherical Harmonics Functions and Wiener Filter

Diffusion tensor imaging (DTI) MRI is a noninvasive imaging method of the cerebral tissues whose fibers directions are not evaluated correctly in the regions of the crossing fibers. For the same reason the high angular resolution diffusion images (HARDI) are used for estimation of the fiber direction in each voxel. One of the main methods to specify the direction of fibers is usage of the spher...

متن کامل

Perfusion Tensor Imaging of Human Skeletal Muscle

Introduction: The ability to non-invasively measure tissue perfusion is critical for assessing the physiological functions of human skeletal muscle in both healthy and disease states. The traditional techniques to measure tissue perfusion in human muscle are invasive and measure only bulk properties which do not render information on either spatial or temporal heterogeneity. Velocity selective ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009