A Simple and Safe Protocol for Preparing Brucella Samples for Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry Analysis.

نویسندگان

  • Jennifer Mesureur
  • Sébastien Ranaldi
  • Valérie Monnin
  • Victoria Girard
  • Sandrine Arend
  • Martin Welker
  • David O'Callaghan
  • Jean-Philippe Lavigne
  • Anne Keriel
چکیده

We describe a simple protocol to inactivate the biosafety level 3 (BSL3) pathogens Brucella prior to their analysis by matrix-assisted laser desorption ionization-time of flight mass spectrometry. This method is also effective for several other bacterial pathogens and allows storage, and eventually shipping, of inactivated samples; therefore, it might be routinely applied to unidentified bacteria, for the safety of laboratory workers.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design, Construction and Calibration of a Laser Ionization Time-of-Flight Mass Spectrometer

A time-of-flight mass spectrometer (TOF-MS) developed in our laboratory at Isfahan University of Technology is described here. The TOF-MS instrument uses laser as the ionization source which provides an opportunity to investigate the ions formed in laser ablation or desorption. The TOF-MS has an ionization chamber containing an accelerator and an ion lens to focus the ions into a one meter line...

متن کامل

Safety and Accuracy of Matrix-Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry for Identification of Highly Pathogenic Organisms

Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) sample preparation methods, including the direct, on-plate formic acid, and ethanol/formic acid tube extraction methods, were evaluated for their ability to render highly pathogenic organisms nonviable and safe for handling in a biosafety level 2 laboratory. Of these, the tube extraction procedure was th...

متن کامل

Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry with a matrix of carbon nanotubes for the analysis of low-mass compounds in environmental samples.

The use of matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) for environmental analysis has been mainlyfocused on qualitative analysis of high-mass molecules, such as toxins, humic acid, and microorganisms. Herein,we describe a novel MALDI-TOF-MS method with a matrix of oxidized carbon nanotubes for analysis of low-mass compounds in environmental sample...

متن کامل

A matrix of 3,4-diaminobenzophenone for the analysis of oligonucleotides by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry

A new matrix of 3,4-diaminobenzophenone (DABP) was demonstrated to be advantageous in the analysis of oligonucleotides by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry. With DABP as a matrix, intact oligonucleotide ions can be readily produced with lower laser powers, resulting in better detection limits, less fragmentation and fewer alkali metal ion adducts compa...

متن کامل

Standardized approach to proteome profiling of human serum based on magnetic bead separation and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry.

BACKGROUND Magnetic bead purification for the analysis of low-abundance proteins in body fluids facilitates the identification of potential new biomarkers by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS). The aims of our study were to establish a proteome fractionation technique and to validate a standardized blood sampling, processing, and storage ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 54 2  شماره 

صفحات  -

تاریخ انتشار 2016