Determinants of target vessel failure in chronic total coronary occlusions after stent implantation. The influence of collateral function and coronary hemodynamics.

نویسندگان

  • Gerald S Werner
  • Philipp Bahrmann
  • Oliver Mutschke
  • Ulf Emig
  • Stefan Betge
  • Markus Ferrari
  • Hans R Figulla
چکیده

OBJECTIVES The goal of this study was to assess the influence of collateral function, coronary hemodynamics, and the angiographic result on the risk of target vessel failure (TVF) after recanalization of a chronic total coronary occlusion (CTO). BACKGROUND Collaterals may have an adverse effect on TVF. METHODS In 111 consecutive patients, a CTO (duration >2 weeks) was successfully recanalized with stent implantation. Collateral function was assessed by intracoronary Doppler flow velocity and pressure recordings distal to the occlusion. Baseline collateral function was determined before the first balloon inflation, and recruitable collateral function after stenting during a balloon reocclusion. Finally, the coronary flow velocity reserve (CFVR) and the fractional flow reserve (FFR) were measured. RESULTS Angiographic follow-up after 5 +/- 4 months in 106 patients showed a reocclusion in 17% and a restenosis in 36%. The major determinants of TVF were the stent length (p < 0.01) and number of implanted stents (p < 0.01). No difference was observed in baseline or recruitable collateral function between patients with and without TVF; 52% of patients had a CFVR >or= 2.0, and only 18% a CFVR >or=2.5 after percutaneous transluminal coronary angioplasty, but neither cutoff-value predicted TVF. A low FFR discriminated patients with reocclusion (0.81 +/- 07 vs. 0.86 +/- 08, p < 0.05) but not with restenosis (0.87 +/- 0.06). CONCLUSIONS This study showed that there is no relation between a well-developed collateral supply and the risk of TVF in recanalized CTOs. This was rather determined by the stented segment length. There was also no adverse effect of the frequently observed impaired CFVR on TVF, whereas a low FFR was associated with a higher risk of reocclusion.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Safety, Efficacy and Clinical Outcome of Direct Stent Implantation

Conventional methods of stenting require predilatation, which potentially increase vessel wall injury and cost of the procedure. In this study, the safety and efficacy of direct AVE-S7 (Medtronic-USA) stent placement were evaluated in 100 patients. Quantitative coronary angiography was performed at the baseline and post-stent. Clinical follow-up was done up to 9 months. In 100 patients (76 male...

متن کامل

Drug-eluting stents for chronic total occlusions make sense, but it is too early to close the discussion.

Stent implantation compared with balloon angioplasty alone has proved not only to increase procedural safety but also to reduce elastic recoil and vascular remodelling and to improve immediate and long-term clinical and angiographic outcomes in patients with coronary artery disease. The use of intravascular ultrasound-guided high pressure stent implantation has reduced the frequency of stent th...

متن کامل

Immediate changes of collateral function after successful recanalization of chronic total coronary occlusions.

BACKGROUND Coronary collaterals are essential to maintain myocardial function in chronic total coronary occlusions (TCOs). The aim of the present study was to assess the collateral circulation in TCOs before coronary angioplasty and to determine the recruitable collateral perfusion after recanalization by use of intracoronary Doppler flow velocimetry. METHODS AND RESULTS In 21 patients with T...

متن کامل

Primary Stenting of Totally Occluded Native Coronary Arteries II (PRISON II): a randomized comparison of bare metal stent implantation with sirolimus-eluting stent implantation for the treatment of total coronary occlusions.

BACKGROUND Sirolimus-eluting stents markedly reduce the risk of restenosis compared with bare metal stents. However, it is not known whether there are differences in effectiveness between bare metal and sirolimus-eluting stents in patients with total coronary occlusions. METHODS AND RESULTS In a prospective, randomized, single-blind, 2-center trial, we enrolled 200 patients with total coronar...

متن کامل

Application of 64-slice spiral computed tomography angiography in a follow-up evaluation after coronary stent implantation: A Chinese clinical study

Background: This study assessed the application value of 64-slice spiral computed tomography angiography (CTA) in a follow-up evaluation of patients receiving coronary stent implantation. Materials and Methods: A total of 468 patients who underwent percutaneous coronary intervention (PCI) at our hospital between January 2013 and October 2016 were selected for this study. Coronary angiography an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 42 2  شماره 

صفحات  -

تاریخ انتشار 2003