The pulsatile nature of the pulmonary capillary blood flow.

نویسندگان

  • M RIGATTO
  • A P FISHMAN
چکیده

The nature of the pulmonary capillary blood flow is fundamental for the understanding both of pulmonary hemodynamics and of respiratory gas exchange. Direct examinations of the surface of the lung in the cat, rabbit, dog and rat (1-5) have indicated that pulmonary capillary blood flow is basically non-pulsatile. On the other hand, experimental studies by Lee and DuBois (6), using the body plethysmograph in man, have suggested that pulmonary capillary blood flow is consistently pulsatile. Their experimental evidence consisted of a rhythmic distortion of the record, synchronous with the heart beat, obtained during breathholding with open glottis, after a single inspiration of nitrous oxide. However, since the first experiences with the pneumotachograph, it has been recognized that cardiovascular pulsations produce rhythmic changes of pressure in the conducting airways of the lungs. These rhythmic changes in intrapulmonary pressure are detected by the pneumotachograph through the changes in the rate of air flow which they produce. This phenomenon, illustrated in the pneumotachographic record of Figure 1, was recognized by Lilly (7) and designated by him as "cardiac air pulse." Subsequently, Bartlett, Brubach and Specht (8) found that rhythmic changes in the pneumotachographic record could be correlated with the pulsations observed in the plethysmographic pressure record obtained during breathholding after an inhalation of ambient air.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Pulsatile Nature of the Pulmonary Capillary Blood

The nature of the pulmonary capillary blood flow is fundamental for the understanding both of pulmonary hemodynamics and of respiratory gas exchange. Direct examinations of the surface of the lung in the cat, rabbit, dog and rat (1-5) have indicated that pulmonary capillary blood flow is basically non-pulsatile. On the other hand, experimental studies by Lee and DuBois (6), using the body pleth...

متن کامل

Pulmonary capillaries are recruited during pulsatile flow.

Capillaries recruit when pulmonary arterial pressure rises. The duration of increased pressure imposed in such experiments is usually on the order of minutes, although recent work shows that the recruitment response can occur in <4 s. In the present study, we investigate whether the brief pressure rise during cardiac systole can also cause recruitment and whether the recruitment is maintained d...

متن کامل

Propagation of blood flow pulse in the normal human pulmonary arterial system. Analysis of the pulsatile capillary flow.

We studied a number of dynamic events associated with the pulsatile flow of blood in the pulmonary arterial system of six healthy men in the supine position. We used the nitrous oxide-body plethysmograph method to record the pulmonary capillary blood flow pulse and the phonocardiogram to determine the time of opening and closing of the pulmonary valve. The pattern of right ventricular ejection ...

متن کامل

PULSATILE MOTION OF BLOOD IN A CIRCULAR TUBE OF VARYING CROSS-SECTION WITH SLIP FLOW

Pulsatile motion of blood in a circular tube of varying cross-section has been developed by considering slip flow at the tube wall and the blood to be a non- Newtonian biviscous incompressible fluid. The tube wall is supposed to be permeable and the fluid exchange across the wall is accounted for by prescribing the normal velocity of the fluid at the tube wall. The tangential velocity of the fl...

متن کامل

Effect of six non-Newtonian viscosity models on hemodynamic parameters of pulsatile blood flow in stenosed artery

A numerical study of hemodynamic parameters of pulsatile blood flow is presented in a stenotic artery with A numerical study of hemodynamic parameters of pulsatile blood flow is presented in a stenotic artery with non-Newtonian models using ADINA. Blood flow was considered laminar, and the arterial wall was considered rigid. Studied stenosis severities were 30, 50, and 70% of the cross-section...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of clinical investigation

دوره 39  شماره 

صفحات  -

تاریخ انتشار 1960