Two-Step Pseudomaximum Amplitude-Based Confidence Interval Estimation for Oscillometric Blood Pressure Measurements

نویسندگان

  • Soojeong Lee
  • Gwanggil Jeon
  • Seokhoon Kang
چکیده

Blood pressure (BP) is an important vital sign to determine the health of an individual. Although the estimation of average arterial blood pressure using oscillometric methods is possible, there are no established methods for obtaining confidence intervals (CIs) for systolic blood pressure (SBP) and diastolic blood pressure (DBP). In this paper, we propose a two-step pseudomaximum amplitude (TSPMA) as a novel approach to obtain improved CIs of SBP and DBP using a double bootstrap approach. The weighted median (WM) filter is employed to reduce impulsive and Gaussian noises in the step of preprocessing. Application of the proposed method provides tighter CIs and smaller standard deviation of CIs than the pseudomaximum amplitude-envelope and maximum amplitude algorithms with Student's t-method.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

On Using Maximum a Posteriori Probability Based on a Bayesian Model for Oscillometric Blood Pressure Estimation

The maximum amplitude algorithm (MAA) is generally utilized in the estimation of the pressure values, and it uses heuristically obtained ratios of systolic and diastolic oscillometric amplitude to the mean arterial pressure (known as systolic and diastolic ratios) in order to estimate the systolic and diastolic pressures. This paper proposes a Bayesian model to estimate the systolic and diastol...

متن کامل

Monitoring Personalized Trait Using Oscillometric Arterial Blood Pressure Measurements

The blood pressure patterns obtained from a linearly or stepwise deflating cuff exhibit personalized traits, such as fairly uniform peak patterns and regular beat geometry; it can support the diagnosis and monitoring of hypertensive patients with reduced sensitivity to fluctuations in Blood Pressure BP over time. Monitoring of personalized trait in Oscillometric Arterial Blood Pressure Measurem...

متن کامل

Rapid oscillometric blood pressure measurement compared to conventional oscillometric measurement.

BACKGROUND There have been few reports studying the necessary interval between blood pressure measurements, after the initial rest period. METHODS Blood pressure was measured in 50 patients using the conventional oscillometric technique (COT) and the rapid oscillometric technique (ROT). RESULTS The difference between COT and ROT was -1.1 / -0.1 mmHg, which was not significantly different (p...

متن کامل

Estimated confidence interval from single blood pressure measurement based on algorithmic fusion

BACKGROUND Current oscillometric blood pressure measurement devices generally provide only single-point estimates for systolic and diastolic blood pressures and rarely provide confidence ranges for these estimates. A novel methodology to obtain confidence intervals (CIs) for systolic blood pressure (SBP) and diastolic blood pressure (DBP) estimates from a single oscillometric blood pressure mea...

متن کامل

Interval Estimation for the Exponential Distribution under Progressive Type-II Censored Step-Stress Accelerated Life-Testing Model Based on Fisher Information

This paper, determines the confidence interval using the Fisher information under progressive type-II censoring for the k-step exponential step-stress accelerated life testing. We study the performance of these confidence intervals. Finally an example is given to illustrate the proposed procedures.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 2015  شماره 

صفحات  -

تاریخ انتشار 2015