XMM – Newton observations of Soft Gamma - ray Repeaters

نویسنده

  • Andrea Tiengo
چکیده

All the confirmed Soft Gamma-ray Repeaters have been observed with the EPIC instrument on the XMM– Newton satellite. We review the results obtained in these observations, providing the most accurate spectra on the persistent X-ray emission in the 1–10 keV range for these objects, and discuss them in the context of the magnetar interpretation.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rotation-Powered Pulsars and Magnetars

I will review the latest developments in understanding the high-energy emission of rotation-powered pulsars and magnetically-powered Anomalous X-ray Pulsars (AXPs) and Soft Gamma-Ray Repeaters (SGRs). These fields have been extremely active in the last few years, both observationally and theoretically, driven partly by new X-ray data from Chandra, XMM-Newton and RXTE. At the same time, the Park...

متن کامل

The first XMM - Newton observations of the Soft Gamma - ray Repeater SGR 1900 + 14 1

A ∼50 ks XMM-Newton observation of SGR 1900+14 has been carried out in September 2005, after almost three years during which no bursts were detected from this soft gamma-ray repeater. The 0.8-10 keV spectrum was well fit by a power law plus blackbody model with photon index Γ=1.9±0.

متن کامل

Soft X - ray emission lines in the afterglow spectrum of GRB 011211 : - a detailed XMM - Newton analysis

We report on an XMM-Newton observation of the X-ray afterglow of the Gamma Ray Burst GRB 011211, originally detected by Beppo-SAX on 11th December 2001. The early afterglow spectrum obtained by XMM-Newton, observed 11 hours after the initial burst, appeared to reveal decaying H-like Kα emission lines of Mg, Si, S, Ar and Ca, arising in enriched material with an outflow velocity of order 0.1c (R...

متن کامل

X-ray spectra from magnetar candidates - III. Fitting SGRs/AXPs soft X-ray emission with non-relativistic Monte Carlo models

Within the magnetar scenario, the “twisted magnetosphere” model appears very promising in explaining the persistent X-ray emission from the Soft Gamma Repeaters and the Anomalous X-ray Pulsars (SGRs and AXPs). In the first two papers of the series, we have presented a 3D Monte Carlo code for solving radiation transport as soft, thermal photons emitted by the star surface are resonantly upscatte...

متن کامل

Quiet but still bright : XMM - Newton observations of the soft gamma - ray repeater SGR 0526 – 66 ⋆

SGR 0526–66 was the first soft gamma-ray repeater (SGR) from which a giant flare was detected in March 1979, suggesting the existence of magnetars, i.e. neutron stars powered by the decay of their extremely strong magnetic field. Since then, very little information has been obtained on this object, mainly because it has been burst-inactive since 1983 and the study of its persistent X–ray emissi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006