Lead dependent tricuspid dysfunction: Analysis of the mechanism and management in patients referred for transvenous lead extraction.
نویسندگان
چکیده
BACKGROUND Lead-dependent tricuspid dysfunction (LDTD) is one of important complications in patients with cardiac implantable electronic devices. However, this phenomenon is probably underestimated because of an improper interpretation of its clinical symptoms. The aim of this study was to identify LDTD mechanisms and management in patients referred for transvenous lead extraction (TLE) due to lead-dependent complications. METHODS Data of 940 patients undergoing TLE in a single center from 2009 to 2011 were assessed and 24 patients with LDTD were identifi ed. The general indications for TLE, pacing system types and lead dwell time in both study groups were comparatively analyzed. The radiological and clinical effi cacy of TLE procedure was also assessed in both groups with precision estimation of clinical status patients with LDTD (before and after TLE). Additionally, mechanisms, concomitant lead-dependent complications and degree (severity) of LDTD before and after the procedure were evaluated. Telephone follow-up of LDTD patients was performed at the mean time 1.5 years after TLE/replacement procedure. RESULTS The main indications for TLE in both groups were similar (apart from isolated LDTD in 45.83% patients from group I). Patients with LDTD had more complex pacing systems with more leads (2.04 in the LDTD group vs. 1.69 in the control group; p = 0.04). There were more unnecessary loops of lead in LDTD patients than in the control group (41.7% vs. 5.24%; p = 0.001). There were no signifi cant differences in average time from implantation to extraction and the number of preceding procedures. Signifi cant tricuspid regurgitation (TR-grade III-IV) was found in 96% of LDTD patients, whereas stenosis with regurgitation in 4%. The 10% frequency of severe TR (not lead dependent) in the control group patients was observed. The main mechanism of LDTD was abnormal leafl et coaptation caused by: loop of the lead (42%), septal leafl et pulled toward the interventricular septum (37%) or too intensive lead impingement of the leafl ets (21%). LDTD patients were treated with TLE and reimplantation of the lead to the right ventricle (87.5%) or to the cardiac vein (4.2%), or surgery procedure with epicardial lead placement following ineffective TLE (8.3%). The radiological and clinical effi cacy of TLE procedure was very high and comparable between the groups I and II (91.7% vs. 94.2%; p = 0.6 and 100% vs. 98.4%; p = 0.46, respectively). Repeated echocardiography showed reduced severity of tricuspid valve dysfunction in 62.5% of LDTD patients. The follow- -up interview confi rmed clinical improvement in 75% of patients (further improvement after cardiosurgery in 2 patients was observed). CONCLUSIONS LDTD is a diagnostic and therapeutic challenge. The main reason for LDTD was abnormal leafl et coaptation caused by lead loop presence, or propping, or impingement the leafl ets by the lead. Probably, TLE with lead reimplantation is a safe and effective option in LDTD management. An alternative option is TLE with omitted tricuspid valve reimplantation. Cardiac surgery with epicardial lead placement should be reserved for patients with ineffective previous procedures.
منابع مشابه
Cardiac pacing in a patient with mechanical tricuspid valve.
89 coaptation, the patient was scheduled for tricuspid valve annuloplasty with concurrent implantation of an epicardial ventricular lead and pacemaker. The operation was preceded by the transvenous extraction of the old ventricular lead. Due to advanced tricuspid valve lesions, a decision was made during surgery to perform artificial tricuspid valve implantation (Medtronic ATS 33 mm). Simultane...
متن کاملTransvenous Pacemaker Lead Removal in Pacemaker Lead Endocarditis with Large Vegetations: A Report of Two Cases
Pacemaker lead endocarditis is treated with total removal of the infected device and proper antibiotics. The outcomes of patients undergoing percutaneous lead extraction for large vegetations (>2 cm) have not yet been shown. In this case report, we present two patients with pacemaker lead endocarditis with large vegetations of maximum diameter 2.4 cm and 3.2 cm. The first patient had multiple v...
متن کاملTransvenous valve-in-valve replacement preserving the function of a transvalvular defibrillator lead.
Although feasibility and efficacy of percutaneous tricuspid valve-in-valve implantation have been established, a transtricuspid pacing or defibrillator lead might preclude this technique: lead damage can cause lead dysfunction resulting in inappropriate or inefficient pacing or shocks. In these cases, lead removal is thought to be the only option. We describe a patient who presented with rapid ...
متن کاملTransjugular lead fragment extraction to improve tricuspid regurgitation
Introduction A 28-year-old-man with a history of human immunodeficiency virus (HIV), end-stage renal disease requiring hemodialysis, and HIV-related cardiomyopathy with a severely reduced left ventricular ejection fraction (LVEF) and severe tricuspid regurgitation (TR) per a transthoracic echocardiogram (TTE) underwent implantation of a singlechamber implantable cardioverter-defibrillator (ICD)...
متن کاملLate resolution of pacemaker lead–related severe tricuspid regurgitation and right ventricular dysfunction after percutaneous lead extraction: A case report and review of the literature
Introduction Endocardial lead–related tricuspid regurgitation (ELTR) is an increasingly recognized complication of cardiac device implantation that can result in right ventricular (RV) dysfunction and right heart failure. Several mechanisms of ELTR have been proposed, including lead impingement on tricuspid valve (TV) leaflets; leaflet perforation; entanglement within the valve apparatus; adher...