In vivo 31P MR spectroscopic imaging of the human prostate at 7 T: safety and feasibility.
نویسندگان
چکیده
(31)P MR spectroscopic imaging of the human prostate provides information about phosphorylated metabolites that could be used for prostate cancer characterization. The sensitivity of a magnetic field strength of 7 T might enable 3D (31)P MR spectroscopic imaging with relevant spatial resolution in a clinically acceptable measurement time. To this end, a (31)P endorectal coil was developed and combined with an eight-channel (1)H body-array coil to relate metabolic information to anatomical location. An extensive safety validation was performed to evaluate the specific absorption rate, the radiofrequency field distribution, and the temperature distribution of both coils. This validation consisted of detailed Finite Integration Technique simulations, confirmed by MR thermometry and B 1+ measurements in a phantom and in vivo temperature measurements. The safety studies demonstrated that the presence of the (31)P endorectal coil had no influence on the specific absorption rate levels and temperature distribution of the external eight-channel (1)H array coil. To stay within a 10 g averaged local specific absorption rate of 10 W/kg, a maximum time-averaged input power of 33 W for the (1)H array coil was allowed. For transmitting with the (31)P endorectal coil, our safety limit of less than 1°C temperature increase in vivo during a 15-min MR spectroscopic imaging experiment was reached at a time-averaged input power of 1.9 W. With this power setting, a second in vivo measurement was performed on a healthy volunteer. Using adiabatic excitation, 3D (31)P MR spectroscopic imaging produced spectra from the entire prostate in 18 min with a spatial resolution of 4 cm(3). The spectral resolution enabled the separate detection of phosphocholine, phosphoethanolamine, inorganic phosphate, and other metabolites that could play an important role in the characterization of prostate cancer.
منابع مشابه
Optimization of clinical target volume delineation using magnetic resonance spectroscopic imaging (MRSI) in 3D conformal radiotherapy of prostate cancer
Background: For the purpose of individual clinical target volume assessment in radiotherapy of prostate cancer, MRSI was used as a molecular imaging modality with MRI and CT images. Materials and Methods: The images of 20 prostate cancer patients were used in this study. The MR and MRSI images were registered with CT ones using non-rigid registration technique. The CT based planning (BP), CT/MR...
متن کاملCharacterization of the human prostate by in vivo P MR spectroscopic imaging at 7 Tesla
Introduction: The metabolism of the human prostate gland is an important subject of study in the determination of pathologies as benign hyperplasia and prostate cancer. Choline compounds involved in phospholipid metabolism may be specific biomarkers for tumor presence and malignancy and can be studied by P MR spectroscopy (1). At a magnetic field strength of 7 Tesla the spectral resolution of i...
متن کاملOptimal timing for in vivo 1H-MR spectroscopic imaging of the human prostate at 3T.
Proton MR spectroscopic imaging ((1)H-MRSI) of the human prostate, which has an interesting clinical potential, may be improved by increasing the magnetic field strength from 1.5T to 3T. Both theoretical and practical considerations are necessary to optimize the pulse timing for spectroscopic imaging of the human prostate at 3T. For in vivo detection of the strongly coupled spin system of citra...
متن کاملPhased array 3D MR spectroscopic imaging of the brain at 7 T.
Ultra-high-field 7 T magnetic resonance (MR) scanners offer the potential for greatly improved MR spectroscopic imaging due to increased sensitivity and spectral resolution. Prior 7 T human single-voxel MR Spectroscopy (MRS) studies have shown significant increases in signal-to-noise ratio (SNR) and spectral resolution as compared to lower magnetic fields but have not demonstrated the increase ...
متن کاملProstate cancer: sextant localization at MR imaging and MR spectroscopic imaging before prostatectomy--results of ACRIN prospective multi-institutional clinicopathologic study.
PURPOSE To determine the incremental benefit of combined endorectal magnetic resonance (MR) imaging and MR spectroscopic imaging, as compared with endorectal MR imaging alone, for sextant localization of peripheral zone (PZ) prostate cancer. MATERIALS AND METHODS This prospective multicenter study, conducted by the American College of Radiology Imaging Network (ACRIN) from February 2004 to Ju...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Magnetic resonance in medicine
دوره 68 6 شماره
صفحات -
تاریخ انتشار 2012