Risk of heparin lock-related bleeding when using indwelling venous catheter in haemodialysis.

نویسندگان

  • H Karaaslan
  • P Peyronnet
  • D Benevent
  • C Lagarde
  • M Rince
  • C Leroux-Robert
چکیده

BACKGROUND The indwelling venous catheter such as Dual-Cath or Twin-Cath is widely used in haemodialysis. Although the manufacturer recommends filling the catheter lumen with heparin after the dialysis session to prevent clotting, little is known about the systemic effects of such a procedure. METHODS Twenty haemodialysis patients with Dual-Cath were studied. Dialysis anticoagulation was achieved by injecting a bolus of dalteparin. The patient/control ratio of activated partial thromboplastin time (aPTT) was determined at the end of the session immediately before and 10 min after locking with 2 ml of undiluted heparin (10,000 U/catheter). We also determined the catheter volume for each patient and measured aPTT immediately before and 10 min after heparin locking with this patient-specific volume. Catheter patency was followed over a 2-week period. RESULTS The aPTT values determined at the end of two consecutive dialysis sessions were nearly normal, respectively 1.29 (+/-0.17) and 1.33 (+/-0.22), whereas all patients had uncoagulable blood (aPTT >3.75) 10 min after locking with 2 ml of heparin. When catheter volumes were individually calculated, they were found to be substantially lower than 2.0 ml (1.21+/-0.12 for the arterial branch and 1.27+/-0.13 for the venous branch). aPTT was only 2.42+/-0.73 10 min after locking with the estimated volumes except in one patient (aPTT >3.75). No catheter clotting was observed despite these smaller locking volumes. CONCLUSIONS A risk of inducing serious bleeding does indeed exist with Dual-Cath heparin locking, especially in postoperative patients. This risk can be reduced by measuring catheter length at the time of placement in order to ensure an appropriate lock volume. Sodium citrate, polygeline, or urokinase are possible alternatives to heparin.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

CVCB Antimicrobial Lock Therapy Study

Medical researchers at Department of Infectious Diseases and Microbiology at the Stamford Hospital in Stamford, CT are studying episodes of central venous catheter-related bacteremia (CVCB) that have become common events in patients with long-term indwelling central venous catheter use. Since no standardized treatment of CVCB exists, novel approaches have been used to salvage infected catheters...

متن کامل

Microbial inactivation properties of a new antimicrobial/antithrombotic catheter lock solution (citrate/methylene blue/parabens)

BACKGROUND Microbial infections are the most serious complications associated with indwelling central venous catheters. A catheter lock solution that is both antibacterial and antithrombotic is needed. The goal of this study was to determine whether a new catheter lock solution containing citrate, methylene blue and parabens has antimicrobial properties against planktonic bacteria and against s...

متن کامل

Sodium citrate 4% locking solution for central venous dialysis catheters--an effective, more cost-efficient alternative to heparin.

BACKGROUND Thrombosis of the central venous haemodialysis catheter compromises dialysis adequacy and catheter survival. Heparin containing catheter-locking solution has been associated with bleeding, interferes with INR (prothrombin time/international normalized ratio) measurements and is costly. Sodium citrate has been used successfully as a catheter-locking solution, but long-term experience ...

متن کامل

Antibiotic lock solutions for the prevention of catheter-related bacteraemia in haemodialysis patients.

OBJECTIVE To investigate the effect of antibiotic lock solutions for preventing catheter-related bacteraemia in patients receiving haemodialysis. DESIGN Retrospective study. SETTING University teaching hospital, Hong Kong. PATIENTS Consecutive patients from March 2006 to April 2007 who had central venous catheter insertion for haemodialysis in our centre were included in this historically...

متن کامل

Exit of catheter lock solutions from double lumen acute haemodialysis catheters--an in vitro study.

BACKGROUND Double lumen dialysis catheters are routinely heparin or citrate 'locked' to maintain patency. Heparin lock-related bleeding episodes and antibiotic lock-related toxicity have been reported. The aim of this study is to quantify the amount of leak during 'lock' procedures and to compare leakage for different double lumen dialysis catheters. METHODS In an experimental, in vitro study...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association

دوره 16 10  شماره 

صفحات  -

تاریخ انتشار 2001