Efficacy of Distortion Correction on Diffusion Imaging: Comparison of FSL Eddy and Eddy_Correct Using 30 and 60 Directions Diffusion Encoding
نویسندگان
چکیده
Diffusion imaging is a unique noninvasive tool to detect brain white matter trajectory and integrity in vivo. However, this technique suffers from spatial distortion and signal pileup or dropout originating from local susceptibility gradients and eddy currents. Although there are several methods to mitigate these problems, most techniques can be applicable either to susceptibility or eddy-current induced distortion alone with a few exceptions. The present study compared the correction efficiency of FSL tools, "eddy_correct" and the combination of "eddy" and "topup" in terms of diffusion-derived fractional anisotropy (FA). The brain diffusion images were acquired from 10 healthy subjects using 30 and 60 directions encoding schemes based on the electrostatic repulsive forces. For the 30 directions encoding, 2 sets of diffusion images were acquired with the same parameters, except for the phase-encode blips which had opposing polarities along the anteroposterior direction. For the 60 directions encoding, non-diffusion-weighted and diffusion-weighted images were obtained with forward phase-encoding blips and non-diffusion-weighted images with the same parameter, except for the phase-encode blips, which had opposing polarities. FA images without and with distortion correction were compared in a voxel-wise manner with tract-based spatial statistics. We showed that images corrected with eddy and topup possessed higher FA values than images uncorrected and corrected with eddy_correct with trilinear (FSL default setting) or spline interpolation in most white matter skeletons, using both encoding schemes. Furthermore, the 60 directions encoding scheme was superior as measured by increased FA values to the 30 directions encoding scheme, despite comparable acquisition time. This study supports the combination of eddy and topup as a superior correction tool in diffusion imaging rather than the eddy_correct tool, especially with trilinear interpolation, using 60 directions encoding scheme.
منابع مشابه
Realistic simulation of artefacts in diffusion MRI for validating post-processing correction techniques
In this paper we demonstrate a simulation framework that enables the direct and quantitative comparison of post-processing methods for diffusion weighted magnetic resonance (DW-MR) images. DW-MR datasets are employed in a range of techniques that enable estimates of local microstructure and global connectivity in the brain. These techniques require full alignment of images across the dataset, b...
متن کاملComprehensive Geometric Distortion Correction for Diffusion Tensor Imaging at Ultra-High Field
EPIs (I-IIa), corresponding FA maps without (I-IIb), with eddy-correction (I-IIc and I-IId) and the final FA maps with comprehensive distortion correction (III): For comparison, eddy correction was performed with the proposed calibration method (c) and FSL (d) and the results were compared with an reference image without distortion (IIIa). To verify the correction quality more easily, the enlar...
متن کاملEffects of Susceptibility Distortion on Fiber Tractography in Diffusion Tensor Imaging
No: 2361 Authors: M Irfanoglu1, Lindsay Walker1, Carlo Pierpaoli1 Institutions: 1NIH, Bethesda, MD Introduction: White matter fiber tractography from diffusion MRI data is widely used in the neuroscience community and in clinical research settings to investigate white matter pathways in the human brain. Diffusion weighted images (DWIs) are generally acquired with echo planar imaging (EPI) and s...
متن کاملDiffusion tensor imaging distortion correction with T 1
Introduction Diffusion weighted single shot spin-echo planer imaging (DW-EPI) is commonly used for diffusion tensor imaging (DTI). DW-EPI is very sensitive to static magnetic field (B0) inhomogeneities (such as that near air-tissue boundary) that produce geometric distortion, primarily along the phase-encoding direction. As a result, artifacts are severe in the frontal and temporal lobes due to...
متن کاملA Novel Algorithm for the Correction of Eddy Current Distortion in Diffusion Weighted Imaging Data
Table 1. A comparison of valid tensors in the DTIs based on DWIs of different strategies of distortion correction. Our method provided the best result, while some other method may increase the number of ill-conditioned tensors (nonpositive definite). (a) (b) (c) (d) Figure 1. A comparison of distortion correction using different approaches. First Row: The simulated dataset; Second Row: The real...