When are solar refrigerators less costly than on-grid refrigerators: A simulation modeling study☆

نویسندگان

  • Leila A. Haidari
  • Shawn T. Brown
  • Patrick Wedlock
  • Diana L. Connor
  • Marie Spiker
  • Bruce Y. Lee
چکیده

BACKGROUND Gavi recommends solar refrigerators for vaccine storage in areas with less than eight hours of electricity per day, and WHO guidelines are more conservative. The question remains: Can solar refrigerators provide value where electrical outages are less frequent? METHODS Using a HERMES-generated computational model of the Mozambique routine immunization supply chain, we simulated the use of solar versus electric mains-powered refrigerators (hereafter referred to as "electric refrigerators") at different locations in the supply chain under various circumstances. RESULTS At their current price premium, the annual cost of each solar refrigerator is 132% more than each electric refrigerator at the district level and 241% more at health facilities. Solar refrigerators provided savings over electric refrigerators when one-day electrical outages occurred more than five times per year at either the district level or the health facilities, even when the electric refrigerator holdover time exceeded the duration of the outage. Two-day outages occurring more than three times per year at the district level or more than twice per year at the health facilities also caused solar refrigerators to be cost saving. Lowering the annual cost of a solar refrigerator to 75% more than an electric refrigerator allowed solar refrigerators to be cost saving at either level when one-day outages occurred more than once per year, or when two-day outages occurred more than once per year at the district level or even once per year at the health facilities. CONCLUSION Our study supports WHO and Gavi guidelines. In fact, solar refrigerators may provide savings in total cost per dose administered over electrical refrigerators when electrical outages are less frequent. Our study identified the frequency and duration at which electrical outages need to occur for solar refrigerators to provide savings in total cost per dose administered over electric refrigerators at different solar refrigerator prices.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Supervisory Control of a Hybrid AC/DC Micro-Grid with Load Shedding Based on the Bankruptcy Problem

In this paper, a supervisory controller is proposed to manage the power flow in a hybrid AC/DC micro-grid for both grid-connected and disconnected modes. When the hybrid AC/DC micro-grid is connected to the utility grid, power surplus or shortage leads to power trade between the micro-grid and the utility grid. In the grid-disconnected mode, the renewable power sources (wind and solar generatio...

متن کامل

Study on Reduction of Energy Consumption of Household Refrigerators-Freezers

In the last quarter of the century, a substantial amount of research work has been conducted on optimization of energy consumption by refrigeration systems and on proper design and construction of household refrigerator-freezers. The importance of such energy optimization schemes stems from the environmental impacts of Freon (R-12) used as the working refrigerant in household refrigerator – fre...

متن کامل

Study on Reduction of Energy Consumption of Household Refrigerators-Freezers

In the last quarter of the century, a substantial amount of research work has been conducted on optimization of energy consumption by refrigeration systems and on proper design and construction of household refrigerator-freezers. The importance of such energy optimization schemes stems from the environmental impacts of Freon (R-12) used as the working refrigerant in household refrigerator – fre...

متن کامل

Vaccine refrigeration

This commentary reviews recent changes in Centers for Disease Control (CDC) vaccine storage guidelines that were developed in response to an investigative report by the Office of the Inspector General. The use of temperature data loggers with probes residing in glycol vials is advised along with storing vaccines in pharmaceutical refrigerators. These refrigerators provide good thermal distribut...

متن کامل

Second Law Based Analysis of Fluid Flow in the Regenerator of Pulse Tube Refrigerators

As a necessary component, regenerator plays an important role in the refrigeration performance of the pulse tube refrigerator. The objective of this research is to investigate the flow characteristics in a porous regenerator of the pulse tube refrigerators, subjected to oscillating flow. The hydrodynamic and thermal behavior of the regenerator is investigated by considering porous media approac...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 35  شماره 

صفحات  -

تاریخ انتشار 2017