Design and construction of a uniaxial cell stretcher.
نویسندگان
چکیده
In vitro mechanical cell stimulators are used for the study of the effect of mechanical stimulation on anchorage-dependent cells. We developed a new mechanical cell stimulator, which uses stepper motor technology and computer control to achieve a high degree of accuracy and repeatability. This device also uses high-performance plastic components that have been shown to be noncytotoxic, dimensionally stable, and resistant to chemical degradation from common culture laboratory chemicals. We show that treatment with glow discharge for 25 s at 20 mA is sufficient to modify the surface of the rubber to allow proper adhesion for polymerization of aligned collagen. We show through finite element analysis that the middle area of the membrane, away from the clamped ends, is predictable, homogeneous, and has negligible shear strain. To test the efficacy of the mechanical stretch, we examined the effect of mechanical stimulation on the production of beta(1)-integrin by neonatal rat cardiac fibroblasts. Mechanical stimulation was tested in the range of 0-12% stretch and 0-10-cycles/min stretch frequency. The fibroblasts respond with an increase in beta(1)-integrin at 3% stretch and a decrease at 6 and 12% stretch. Stretch frequency was found to not significantly effect the concentration of beta(1)-integrin. These studies yield a new and improved mechanical cell stimulator and demonstrate that mechanical stimulation has an effect on the expression of beta(1)-integrin.
منابع مشابه
OPTIMAL DESIGN OF COLUMNS FOR AN INTERMEDIATE MOMENT FRAME UNDER UNIAXIAL MOMENT AND AXIAL LOADS
The present study addresses optimal design of reinforced concrete (RC) columns based on equivalent equations considering deformability regulations of ACI318-14 under axial force and uniaxial bending moment. This study contrary to common approaches working with trial and error approach in design, at first presents an exact solution for intensity of longitudinal reinforcement in column section by...
متن کاملThe Types and Usage of Building materials in the West Iwan of Takht-e Soleymān
The western iwan of the Takht-e Soleymān is one of the most important buildings in this area. Based on some accounts, this iwan was constructed during the Sāssānid period and the Ilkhanate kings restored it after 700 years. This unique structure is statically unstable and needs strengthening. To this end, becoming familiar with the building materials and their use in this structure are importan...
متن کاملThe Types and Usage of Building materials in the West Iwan of Takht-e Soleymān
The western iwan of the Takht-e Soleymān is one of the most important buildings in this area. Based on some accounts, this iwan was constructed during the Sāssānid period and the Ilkhanate kings restored it after 700 years. This unique structure is statically unstable and needs strengthening. To this end, becoming familiar with the building materials and their use in this structure are importan...
متن کاملDesign and Construction of Load Cell of a Three Point Hitch Dynamometer for Tractor John Deere 3140
Measurement of the values of forces in tractor arms is of great importance due to draft of agricultural equipment. These values can be used for testing and evaluation of the agricultural machinery, selection of suitable tractor, etc. The tools which are used for measurement of the forces are called dynamometer. The main objective of the present study was to design and evaluate a load cell for i...
متن کاملDesign and Construction of Load Cell of a Three Point Hitch Dynamometer for Tractor John Deere 3140
Measurement of the values of forces in tractor arms is of great importance due to draft of agricultural equipment. These values can be used for testing and evaluation of the agricultural machinery, selection of suitable tractor, etc. The tools which are used for measurement of the forces are called dynamometer. The main objective of the present study was to design and evaluate a load cell for i...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- American journal of physiology. Heart and circulatory physiology
دوره 279 6 شماره
صفحات -
تاریخ انتشار 2000