Detection volume of simulated electrode systems for recording sphincter muscle electromyogram.
نویسندگان
چکیده
BACKGROUND Recording surface electromyogram (EMG) signals from sphincter muscles has become of increasing interest due to potential applications in diagnosis or investigation of the mechanisms of incontinence. Recently developed probes allow high-resolution detection of EMG signal from the external anal sphincter. One of the main issues in the interpretation of experimental signals is the detection volume of the recording electrodes. METHODS An analytical model of generation of EMG from the anal sphincter was applied to simulate single fiber action potentials varying the fiber length, conductivity and thickness of the mucosa, shape of the electrodes, and detection system (monopolar, bipolar, and double differential). RESULTS The new probe is more selective than classical probes with big electrodes and large interelectrode distance. The decay of the recorded surface EMG action potentials with distance of the fiber was faster for increasing depth than axial distance (this is due to the geometry of the volume conductor, as indicated by comparison with simulations with a planar volume conductor). Point electrodes led to smaller detection volumes than rectangular electrodes, and the double differential system was the most selective recording configuration. The relative decrease of the detected potential generated by more distant fibers was lower for increasing thickness and conductivity of the mucosa. End-of-fiber components are enhanced by the circular geometry of sphincter muscles with respect to the case of a planar volume conductor. CONCLUSIONS The detection volume of EMG recording systems from sphincter muscles extends more in the axial than in the depth direction and is affected by many parameters that cannot be estimated in practical situations, thus introducing a rather large variability in the muscle portion investigated among subjects. More selective information can be obtained using the recently developed multi-channel probe with respect to classical probes. Selectivity is increased with small electrodes and double differential recordings.
منابع مشابه
[New trends in urodynamic investigation].
Urodynamic approach to the disorders of the urinary tract has been based on the knowledge of anatomy and neurophysiology of this abnormality. The development of this field included uroflowmetry, cystometry, urethral profilometry, and electromyogram of the external sphincter. In addition to these investigations new trends in urodynamic field were reviewed. With the advent of muscle biochemistry ...
متن کاملRemoving ECG Artifact from the Surface EMG Signal Using Adaptive Subtraction Technique
Background: The electrocardiogram artifact is a major contamination in the electromyogram signals when electromyogram signal is recorded from upper trunk muscles and because of that the contaminated electromyogram is not useful.Objective: Removing electrocardiogram contamination from electromyogram signals.Methods: In this paper, the clean electromyogram signal, electrocardiogram artifact and e...
متن کاملDetecting the unique representation of motor-unit action potentials in the surface electromyogram.
This study investigated the relative proportion of motor-unit action potentials that are uniquely represented in the simulated and experimental surface electromyogram (EMG). Two hundred motor units were simulated in a cylindrical anatomical system. Action potentials for each motor unit were generated with a model and then compared with those of other motor units. Pairs of motor units were consi...
متن کاملLength Tension Function of Puborectalis Muscle: Implications for the Treatment of Fecal Incontinence and Pelvic Floor Disorders
BACKGROUND/AIMS External anal sphincter (EAS) and puborectalis muscle (PRM) play important role in anal continence function. Based on length-tension measurement, we recently reported that the human EAS muscle operates at short sarcomere length under phys-iological conditions. Goal of our study was to determine if PRM also operates at the short sarcomere length. METHODS Length-tension relation...
متن کاملResearch on Recording and Filtering Electromyogram (emg) Signals
In this article will be presented a novel way to record and filter the Electromyogram (EMG) signal. EMG signals are generated when the muscles activates. In our case the user’s eye muscle movements in any direction will be recorded and filtered, so we will be able to observe when the user looks with his/her eyes up, down, left or right. In this article we use the non-invasive EMG signal recordi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Medical engineering & physics
دوره 30 7 شماره
صفحات -
تاریخ انتشار 2008