High Structural Stress and Presence of Intraluminal Thrombus Predict Abdominal Aortic Aneurysm 18F-FDG Uptake: Insights From Biomechanics.

نویسندگان

  • Yuan Huang
  • Zhongzhao Teng
  • Maysoon Elkhawad
  • Jason M Tarkin
  • Nikhil Joshi
  • Jonathan R Boyle
  • John R Buscombe
  • Timothy D Fryer
  • Yongxue Zhang
  • Ah Yeon Park
  • Ian B Wilkinson
  • David E Newby
  • Jonathan H Gillard
  • James H F Rudd
چکیده

BACKGROUND Abdominal aortic aneurysm (AAA) wall inflammation and mechanical structural stress may influence AAA expansion and lead to rupture. We hypothesized a positive correlation between structural stress and fluorine-18-labeled 2-deoxy-2-fluoro-d-glucose (18F-FDG) positron emission tomography-defined inflammation. We also explored the influence of computed tomography-derived aneurysm morphology and composition, including intraluminal thrombus, on both variables. METHODS AND RESULTS Twenty-one patients (19 males) with AAAs below surgical threshold (AAA size was 4.10±0.54 cm) underwent 18F-FDG positron emission tomography and contrast-enhanced computed tomography imaging. Structural stresses were calculated using finite element analysis. The relationship between maximum aneurysm 18F-FDG standardized uptake value within aortic wall and wall structural stress, patient clinical characteristics, aneurysm morphology, and compositions was explored using a hierarchical linear mixed-effects model. On univariate analysis, local aneurysm diameter, thrombus burden, extent of calcification, and structural stress were all associated with 18F-FDG uptake (P<0.05). AAA structural stress correlated with 18F-FDG maximum standardized uptake value (slope estimate, 0.552; P<0.0001). Multivariate linear mixed-effects analysis revealed an important interaction between structural stress and intraluminal thrombus in relation to maximum standardized uptake value (fixed effect coefficient, 1.68 [SE, 0.10]; P<0.0001). Compared with other factors, structural stress was the best predictor of inflammation (receiver-operating characteristic curve area under the curve =0.59), with higher accuracy seen in regions with high thrombus burden (area under the curve =0.80). Regions with both high thrombus burden and high structural stress had higher 18F-FDG maximum standardized uptake value compared with regions with high thrombus burdens but low stress (median [interquartile range], 1.93 [1.60-2.14] versus 1.14 [0.90-1.53]; P<0.0001). CONCLUSIONS Increased aortic wall inflammation, demonstrated by 18F-FDG positron emission tomography, was observed in AAA regions with thick intraluminal thrombus subjected to high mechanical stress, suggesting a potential mechanistic link underlying aneurysm inflammation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High Structural Stress and Presence of Intraluminal Thrombus Predict Abdominal Aortic Aneurysm 18F-FDG Uptake

Abdominal aortic aneurysm (AAA) is a localized enlargement of the aorta, conventionally diagnosed when the maximum anteroposterior vessel diameter exceeds 3.0 cm. AAAs are most prevalent in elderly men and are frequently asymptomatic until point of rupture, which is the catastrophic failure of the aneurysmal wall associated with an overall mortality rate between 65% and 85%. Current management ...

متن کامل

Intraluminal thrombus and risk of rupture in patient specific abdominal aortic aneurysm - FSI modelling.

Recent numerical studies of abdominal aortic aneurysm (AAA) suggest that intraluminal thrombus (ILT) may reduce the stress loading on the aneurysmal wall. Detailed fluid structure interaction (FSI) in the presence and absence of ILT may help predict AAA rupture risk better. Two patients, with varied AAA geometries and ILT structures, were studied and compared in detail. The patient specific 3D ...

متن کامل

Multifactorial relationship between 18F-fluoro-deoxy-glucose positron emission tomography signaling and biomechanical properties in unruptured aortic aneurysms.

BACKGROUND The relationship between biomechanical properties and biological activities in aortic aneurysms was investigated with finite element simulations and 18F-fluoro-deoxy-glucose (18F-FDG) positron emission tomography. METHODS AND RESULTS The study included 53 patients (45 men) with aortic aneurysms, 47 infrarenal (abdominal aortic) and 6 thoracic (thoracic aortic), who had ≥1 18F-FDG p...

متن کامل

Biochemomechanics of intraluminal thrombus in abdominal aortic aneurysms.

Most computational models of abdominal aortic aneurysms address either the hemodynamics within the lesion or the mechanics of the wall. More recently, however, some models have appropriately begun to account for the evolving mechanics of the wall in response to the changing hemodynamic loads. Collectively, this large body of work has provided tremendous insight into this life-threatening condit...

متن کامل

Biomechanics of abdominal aortic aneurysm in the presence of endoluminal thrombus: experimental characterisation and structural static computational analysis.

OBJECTIVES To evaluate the role played by biomechanical and geometrical parameters of endoluminal thrombus and of aortic wall on abdominal aortic aneurysm (AAA) behaviour. MATERIALS AND METHODS Tensile tests on 21 AAA thrombus specimens from six patients undergoing AAA repair and numerical evaluation of aneurysmal aortic wall stress and strain distribution. Parameters of the analysis were lum...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation. Cardiovascular imaging

دوره 9 11  شماره 

صفحات  -

تاریخ انتشار 2016