Dose tolerance limits and dose volume histogram evaluation for stereotactic body radiotherapy

نویسندگان

  • Jimm Grimm
  • Tamara LaCouture
  • Raymond Croce
  • Inhwan Yeo
  • Yunping Zhu
  • Jinyu Xue
چکیده

Almost 20 years ago, Emami et al. presented a comprehensive set of dose tolerance limits for normal tissue organs to therapeutic radiation, which has proven essential to the field of radiation oncology. The paradigm of stereotactic body radiotherapy (SBRT) has dramatically different dosing schemes but, to date, there has still been no comprehensive set of SBRT normal organ dose tolerance limits. As an initial step toward that goal, we performed an extensive review of the literature to compare dose limits utilized and reported in existing publications. The impact on dose tolerance limits of some key aspects of the methods and materials of the various authors is discussed. We have organized a table of 500 dose tolerance limits of normal structures for SBRT. We still observed several dose limits that are unknown or not validated. Data for SBRT dose tolerance limits are still preliminary and further clinical trials and validation are required. This manuscript presents an extensive collection of normal organ dose tolerance limits to facilitate both clinical application and further research.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluating Published Skin Dose Tolerance Limits for Stereotactic Body Radiation Therapy of Lung Cancer

Objectives: Published local control rates for certain stereotactic body radiotherapy (SBRT) lung cancer treatments have exceeded 97%, but several serious adverse events have been reported. No five-year normal tissue complication probability (NTCP) statistical analysis SBRT results have been published yet for skin. While we expectantly await these publications, the goal of this manuscript is to ...

متن کامل

Estimated Risk Level of Unified Stereotactic Body Radiation Therapy Dose Tolerance Limits for Spinal Cord.

A literature review of more than 200 stereotactic body radiation therapy spine articles from the past 20 years found only a single article that provided dose-volume data and outcomes for each spinal cord of a clinical dataset: the Gibbs 2007 article (Gibbs et al, 2007(1)), which essentially contains the first 100 stereotactic body radiation therapy (SBRT) spine treatments from Stanford Universi...

متن کامل

The evaluation of lung doses for radiation pneumonia risk in stereotactic body radiotherapy: A comparison of intensity modulated radiotherapy, intensity modulated arc therapy, cyberknife and helical tomotherapy

Background: Radiation Pneumonia (RP) is one of the most extensive side effects in Stereotactic Body Radiotherapy (SBRT) of lung cancer. SBRT are performed by means of Intensity Modulated Radiotherapy (IMRT), Intensity Modulated Arc Therapy (IMAT), CyberKnife (CK) or Helical Tomotherapy (HT) treatment methods. In this study, we performed a plan study to determine the plan parameter such as the M...

متن کامل

Dosimetric Comparison of Different Prescription Modes in Lung Stereotactic Body Radiation Therapy

The purpose of this study was to compare the dose-volume statistics of stereotactic body radiotherapy (SBRT) for lung cancer between planning target volume (PTV): D95 and gross tumor volume (GTV): D99 dose prescriptions using Monte Carlo (MC) calculation. Plans for 183 patients treated between October 2010 and April 2013 were generated based on four-dimensional (4D) computed tomography (CT) und...

متن کامل

Low toxicity for lung tumors near the mediastinum treated with stereotactic body radiation therapy.

PURPOSE To report the local control, survival, and low toxicity observed at the Cooper University Hospital CyberKnife Center post stereotactic body radiation therapy (SBRT) in the treatment of lung tumors near the mediastinum. METHODS AND MATERIALS Twenty-four medically inoperable lung cancer patients with tumors near the mediastinum were treated using the Accuray CyberKnife system (Accuray, ...

متن کامل