Gas exchange during mechanical ventilation and spontaneous breathing. Intermittent mandatory ventilation after open heart surgery.

نویسندگان

  • G Wolff
  • J X Brunner
  • E Grädel
چکیده

Pulmonary gas exchange rates in eight patients after open heart surgery were studied during weaning from the ventilator. We investigated continuous positive pressure ventilation (CPPV), intermittent mandatory ventilation (IMV) and spontaneous breathing with continuous positive airway pressure (CPAP). During each mode of ventilation we measured: CO2 production (VCO2), O2 consumption (VO2), cardiac output (CO), PaO2, Qs/QT and functional residual capacity (FRC). In addition, we analyzed in each single breath: tidal volume (VT), series dead space volume (Vds), alveolar ventilation, alveolar efficiency for CO2 elimination (alv eff CO2) and end-tidal CO2 concentration (FCO2et). We compared the results of CPPV, IMV and CPAP and the mandatory breaths (MB) with the spontaneous breaths (SB) measured during IMV. CO was low during CPPV, when the patient still deeply sedated; it was increased in IMV and remained constant in the following CPAP period. VCO2 and VO2 did not differ significantly when switching from IMV to CPAP; therefore, work due to breathing seemed not to be reduced by the mandatory breath during IMV. Oxygenation (PaO2, Qs/QT) did not change significantly when switching from one mode to the other. FRC was constant when changing from CPPV to IMV, did not alter within the IMV-cycle and was reduced significantly when switching from IMV to CPAP. Dead space ventilation was reduced in SB (compared to MB). The latter result is discussed on the basis of two mechanisms: Vds was reduced and alv eff CO2 was increased. We conclude that compared to CPPV, IMV decreases mean alveolar pressure and reduces dead space ventilation at constant FRC and with constant oxygenation. This may explain why, in the weaning process, IMV makes it possible to start spontaneous breathing very early.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Spontaneous ventilation test vs intermittent mandatory ventilation. An approach to weaning after coronary bypass surgery.

T he timing of tracheal extubation after open heart surgery may accelerate recovery without increasing mortality. However, the manner of weaning from controlled mechanical ventilation (CMV) varies widely in different centers. Since 1972 an alternative means of ventilatory “support” advocated is that of intermittent mandatory ventilation ( IMV), in which an inadequate minute volume produced by t...

متن کامل

A comparison of four methods of weaning patients from mechanical ventilation. Spanish Lung Failure Collaborative Group.

BACKGROUND Weaning patients from mechanical ventilation is an important problem in intensive care units. Weaning is usually conducted in an empirical manner, and a standardized approach has not been developed. METHODS We carried out a prospective, randomized, multicenter study involving 546 patients who had received mechanical ventilation for a mean (+/- SD) of 7.5 +/- 6.1 days and who were c...

متن کامل

Should Intermittent Mandatory Ventilation Be Abolished?

Intermittent mandatory ventilation (IMV) was introduced nearly 50 years ago. Despite the initial fanfare and early adoption by many, the role of IMV continues to be questioned. The use of small tidal volumes complicates the application of IMV, and issues with work of breathing, weaning and lack of clear advantages have many calling for a moratorium on its use. Spontaneous breathing, however, ha...

متن کامل

Synchronized intermittent mandatory ventilation with and without pressure support ventilation in weaning patients with COPD from mechanical ventilation.

This prospective study compared two weaning modalities in COPD patients requiring mechanical ventilation (MV) for acute respiratory failure. Nineteen patients with COPD were studied when their precipitating illness was controlled. Although they satisfied the conventional bedside weaning criteria, they could not tolerate any reduction in the respirator rate below 10 cycles/min. At this time, pat...

متن کامل

A lightweight mainstream capnometer with very low dead space volume is useful monitor for neonates with spontanous and mechanical ventilation: Pilot study

Objects: The purpose of this study was to observe a correlation between PETCO2 and PaCO2 in intubated neonates under intermittent mandatory ventilation with spontaneous breathing. Material and methods: A total of 55 paired PETCO2 measured by mainstream capnometry and PaCO2 values were obtained from 4 intubated neonates in our neonatal intensive care units at Nagano Children’s Hospital, Nagano, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Chest

دوره 90 1  شماره 

صفحات  -

تاریخ انتشار 1986