Unpredictable fluctuations in transcutaneous pCO2 from capillary blood gas determinations.

نویسندگان

  • G J Kost
  • J L Chow
  • M Kenny
چکیده

Transcutaneous pCO2 electrode response time was optimized by use of a new electrode filling solution composed of NaCl/NaHCO3 electrolyte buffer (100 and 20 mmol/L, respectively) in an equivolume mixture of glycerol and water. The 95% response time to a step change in pCO2 was 49.9 +/- 2.8 s (mean +/- SD) when there was no spacer between the membrane and glass of the electrode. Use of this filling solution during monitoring of severely ill premature infants with cardiopulmonary disease allowed identification of large, unpredictable transient changes in transcutaneous pCO2, and therefore presumably in arterial pCO2, that occurred during capillary blood gas sampling. The changes, which occurred in 19 of 20 samplings, ranged from -1.06 + 2.53 kPa (-8 to +19 Torr). The maximum relative change observed was +29%. These results indicate that the standard protocol for capillary blood collection induces significant transient fluctuations in blood gas tensions. We believe these fluctuations decrease the reliability of capillary pCO2 values for use in clinical management in patient populations similar to ours.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Transcutaneous and Capillary Measurement of PCO2 in Hypercapnic Subjects.

BACKGROUND Measurement of PCO2 is vital in determining effective alveolar ventilation. However, obtaining capillary PCO2 by a skin prick of the earlobe is painful, and nocturnal measurements disturb sleep. End-expiratory measurement of PCO2 is also well established, but there is a low precision in predicting arterial or capillary CO2. The purpose of the study was to evaluate nocturnal measureme...

متن کامل

Changes in transcutaneous oxygen tension during capillary blood-gas sampling.

With a Radiometer TCM-1 oxygen monitor, we followed the fluctuations in transcutaneous oxygen tension (ptcO2) during capillary blood collection from a heel prick. Thirty premature infants who presented with some respiratory compromise showed unpredictably increased (43 of 125 observations) or decreased (82 of 125 observations) values during this blood-sampling process. The fluctuation exceeded ...

متن کامل

Transcutaneous and capillary pCO2 and pO2 measurements in healthy adults.

Transcutaneous carbon dioxide and oxygen tensions (tc-pCO2 and tc-pO2) were measured in seven healthy adult volunteers during hyperventilation in atmospheric air and during CO2 inhalation. Three skin sensors were applied to each subject: an O2 electrode, a CO2 electrode, and a combined O2-CO2 electrode, each heated to 44 degrees C. We observed close correlation between tc-pCO2 and capillary-pCO...

متن کامل

Comparison of capillary and arterial blood gas measurements in neonates.

One hundred and fifty eight paired arterial and capillary blood samples were obtained from 41 sick preterm infants in their first week of life and the pH, and PCO2, and PO2 concentrations were measured. Half of the capillary samples were obtained from unwarmed heels and half from heels warmed to 40 degrees C. A potentially significant discrepancy (arbitrarily defined as 0.05 units for pH. 1 kPa...

متن کامل

Comparison of blood gas values in arterial and venous blood.

OBJECTIVE To compare pH and PCO2 values of simultaneously obtained arterial, arterialized capillary, and venous blood samples and also to compare oxygen saturation (ASaO2) measured in arterial blood and oxygen saturation by pulse oximetry (PSaO2). METHODS Prospective study was done in the children admitted in the Pediatric Intensive Care Unit of Christian Medical College Hospital Vellore, req...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 28 7  شماره 

صفحات  -

تاریخ انتشار 1982