Development and Application of Contact-type Line-focus Ultrasonic Probe

نویسندگان

  • Hirotsugu Inoue
  • Kikuo Kishimoto
چکیده

A contact-type line-focus ultrasonic probe has been developed. The probe is composed of a quarter cylindrical wedge and a piezoelectric transducer attached to its cylindrical surface. A key feature of the developed probe is that longitudinal wave is incident to the testing object at all angles from 0° to 90° simultaneously. Basic characteristics of the probe have been examined by visualizing ultrasonic wave field and by evaluating the directivity. Some applications of the probe have been also investigated. It has been shown that the probe can transmit and receive Rayleigh and generalized Lamb waves in objects having relatively wide range of mechanical properties. It has been also shown that this probe can be applied to TOFD method.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development of Ultrasonic Line-Focus SH-Wave Probe

A line-focus ultrasonic SH-wave probe is developed for possible application to TOFD method. The probe is composed of a quarteror half-cylindrical wedge and a piezoelectric transducer adhered to the cylindrical surface of the wedge. An SH-wave pulse with cylindrical wave front is generated by the transducer, transmitted to the wedge, and focused on a line at the bottom surface of the wedge. Henc...

متن کامل

An In-line Ultrasonic Viscometer*

An in-line viscometer is valuable to the control of a flow process, particularly a non-Newtonian flow because its viscosity is shear-rate dependent and thus requires continuous monitoring. Currently available in-line viscometers are mostly of the probe design [1] and may obstruct the flow pattern, causing plugging problem in flows with suspended particles. A probe-type viscometer generally meas...

متن کامل

Ultrasonic scaler oscillations and tooth-surface defects.

Damage to tooth root surfaces may occur during ultrasonic cleaning with both piezoelectric and magnetostrictive ultrasonic scalers. It is unclear which mechanism causes more damage or how their mechanism of action leads to such damage. Our null hypothesis is that tooth-surface defect dimensions, resulting from instrumentation with ultrasonic scalers, are independent of whether the scaler probe ...

متن کامل

Difference between efficiency of ultrasound treatments above and below the membrane surface in membrane clarification of pomegranate juice

Microfiltration can clarify pomegranate juice; however, fouling is a limiting phenomenon in the process. In current work ultrasound was applied above and below the membrane surface to reduce fouling after removing temperature effect. A hydrophilic mixed cellulose ester membrane with pore size of 0.45 μm was used in lab scale flat sheet module. Membrane module was placed above and below the ultr...

متن کامل

Difference between efficiency of ultrasound treatments above and below the membrane surface in membrane clarification of pomegranate juice

Microfiltration can clarify pomegranate juice; however, fouling is a limiting phenomenon in the process. In current work ultrasound was applied above and below the membrane surface to reduce fouling after removing temperature effect. A hydrophilic mixed cellulose ester membrane with pore size of 0.45 μm was used in lab scale flat sheet module. Membrane module was placed above and below the ultr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006