A chemiluminescence method to detect malondialdehyde in plasma and urine.
نویسندگان
چکیده
A highly sensitive and convenient method to detect malondialdehyde (MDA) in specimens of plasma and urine was developed using high-performance liquid chromatography combining chemiluminescence detection. MDA was separated through a reverse-phase C18 column at a flow rate of 0.8 ml min(-1). It was then detected by a chemiluminescence detector. Variables that affected chemiluminescence reaction, including mobile phase, flow rate, chemiluminescence reagent, parameters of the photomultiplier tube, and temperature, were studied. This assay was linear from 0.50 to 50 μmol L(-1), with limits of detection and quantification of 0.08 and 0.30 μmol L(-1), respectively. The recoveries were in the range of 92.2 to 98.5%, and the intra- and interday reproducibilities were obtained with relative standard deviations of less than 4% and less than 6%, respectively. MDA in plasma and urine was stable for 12 h at 4°C. MDA levels were 2.74, 3.19, and 3.20 μmol L(-1) for plasma and 1.25, 2.04, and 1.58 μmol L(-1) for urine, respectively. The proposed method is simple, rapid, and sensitive with low cost. Taken together, this method can be suitable for detecting MDA in tissue and feed specimens.
منابع مشابه
Terbium Sensitized Chemiluminescence Method for the Determination of Rabeprazole -Application to Pharmaceutical Analysis and Dissolution Studies
A simple and sensitive chemiluminescence-based method was established for the determination of rabeprazole.The proposed method was based on the enhancing effect of rabeprazole on Ce(IV)-Na2SO3 -Tb(III) chemiluminescence reaction. A possible mechanism was discussed for chemiluminescence system by studying UV-Vis, fluorescence and chemiluminescence spectra. The effects of va...
متن کاملChemiluminescence Determination of Atropine using Luminol-Hemin-H2O2 System
A sensitive and fast chemiluminescence (CL) method has been described for the direct determination of atropine. The method is based on the quenching effect of atropine on the CL signals of the luminol– H2O2 reaction catalyzed by hemin in an alkaline medium. Hemin could strongly enhance the chemiluminescence of the luminol–H2O2 system. The luminophor of the luminol–H2O2–hemin CL system was ident...
متن کاملChemiluminescence Determination of Hydroxyzine and its Metabolite Cetirizine
A chemiluminescence (CL) method has been developed for the determination of Hydroxyzine (Hyd) and its metabolite Cetirizine (Cet). The method is based on sensitizing effect of Cet and Hyd on the weak CL reaction between Ru(phen)32+ and acidic Ce(IV). A mechanism for the CL reaction has been proposed on the basis of UV-Vis, fluorescent and CL spectra. By using the recommended procedure, the cali...
متن کاملChemiluminescence determination of melamine with Luminol-K3Fe(CN)6 system
A sensitive chemiluminescence (CL) method was developed for determining melamine in urine and plasma samples based on the fact that melamine can remarkably enhance the chemiluminescence of Luminol-K3 Fe(CN)6 system in alkaline medium. The determination conditions were optimized. Under optimum conditions, the chemiluminescence intensity had a good linear relationship with melamine in the range o...
متن کاملDirect Chemiluminescence Determination of Oxymorphone Using Potassium Permanganate and Polyphosphoric Acid
Abstract A simple and sensitive chemiluminescence (CL) method was developed for direct quantification of oxymorphone, a µ opioid agonist that is approximately 10 times more potent than morphine. In this method potassium permanganate in polyphosphoric acid was used as CL reagent. Using this method, oxymorphone can be determined over the concentration ranges 13.5-337.8 ng mL-1 and 0.34-6.76...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Analytical biochemistry
دوره 443 1 شماره
صفحات -
تاریخ انتشار 2013