DØ Upgrade for RUN II
نویسنده
چکیده
The DØ detector at The Fermilab Tevatron is undergoing a major upgrade to prepare for data taking with luminosities reaching 2× 10 cm s. The upgrade includes a new central tracking array, new muon detector components and electronic upgrades to many subsystems. The DØ upgraded detector will be operational for RUN II in spring 2000.
منابع مشابه
1 M ay 2 00 3 B PHYSICS AT DØ
The DØ detector at FNAL has undergone a significant upgrade for its present Run II data taking period, allowing for a broad B physics programme. This report focuses on studies performed on a sample of approximately 75· 10 3 inclusive J/ψ events. Preliminary results on mass and lifetime measurements and prospects for flavour tagging are presented.
متن کامل/ 02 02 04 7 v 1 2 8 Fe b 20 02 The DØ Detector at the Fermilab Tevatron in Run 2
The DØ (DZERO) Detector at Fermilab is currently collecting data since March 1, 2001, called Run 2. The detector has undergone an extensive upgrade to participate in the Run 2 data taking. The design of the detector meets the requirements of the high luminosity environment provided by the accelerator. This paper describes the upgraded detector subsystems and gives an outline of the physics pote...
متن کاملScintillation Counters for the DØ Muon Upgrade
We present the results of an upgrade to the DØ muon system. Scintillating counters have been added to the existing central DØ muon system to provide rejection for cosmic ray muons and out-of-time background, and to provide additional fast timing information for muons in an upgraded Tevatron. Performance and results from the 1994–1996 Tevatron run are presented. Submitted to Nuclear Instruments ...
متن کاملThe DØ Detector at the Fermilab Tevatron in Run
The DØ (DZERO) Detector at Fermilab has been collecting data since March 1, 2001. The detector has undergone an extensive upgrade to participate in the Run 2 data taking. The design of the detector meets the requirements of the high lumi-nosity environment provided by the accelerator. This paper describes the upgraded detector subsystems and gives an outline of the physics potentials associated...
متن کامل/ 02 10 00 2 v 1 3 0 Se p 20 02 1 The DØ Detector for Run II
The general purpose DØ collider detector at the Fermilab Tevatron has undergone major upgrades for Run II. We describe the current status and performance of the DØ detector.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 1999