Design and Implementation of Long-Term Single-Lead ECG Monitor
نویسندگان
چکیده
Some heart diseases need long-term monitoring to diagnose. In this paper, we present a wearable single lead ECG monitoring device with low power consumption based on MSP430 and single-lead ECG front-end AD8232, which could acquire and store patient’s ECG data for 7 days continuously. This device is available for long-term wearing with a small volume. Also, it could detect user’s motion status with an acceleration sensor and supports Bluetooth 4.0 protocol. So it could be expanded to be a dynamic heart rate monitor and/or sleep quality monitor combined with smart phone. The device has huge potential of application for health care of human daily life.
منابع مشابه
“Short Paper” The Effect of Short Term and Long Term Feeding of Barley Seed with or Without eCG on Reproductive Performance of Goat During Breeding and Out Breeding Seasons
Nutritional and hormonal programs are one of the important ways of improving goat reproductive performance. Therefore, the present study was conducted to investigate the effect of using barley seed and eCG at the same time on the reproductive performance of goat in nomadic breeding conditions. The number of 60 goats of two to three-year-old in the breeding season and 60 goats of three to four-y...
متن کاملDesign of a Non-intrusive 2-lead ECG System Using the Active Insulated Electrode
For patients at risk of developing cardiovascular complications, it is important to monitor their heart signal to ensure proper functioning of their heart and a natural, healthy cardiac cycle. Preferably, this monitoring should be done on a continuous and long-term basis. Both of these objectives can be achieved using the electrocardiogram. While the traditional 12-lead ECG is currently used in...
متن کاملDeriving the 12-lead Electrocardiogram
This paper proposes a lead method and a processing means for monitoring the 12-lead electrocardiogram (ECG) with four standard leads. Leads I, II of the M-L leads and leads V1, V6 of the chest leads are used to record the ECG signals. The ECG waveforms of leads V2 through V5 are derived from the input signals using the least squares method based on the Frank torso model. This method makes it po...
متن کاملCatecholamine Contents of Different Region of Adult Rat Brain Are Altered Following Short and Long-term Exposures to Pb+2
Catecholamine is a group of neurotransmitters that is believed to be responsible for the normal function of animal brain. Physiological and behavioral changes of human body have been reported due to the damage of the brain function following lead exposure. Due to the assumption of lead disposal in brain tissue with two year for its half-life, which results in alteration of brain function, we in...
متن کاملCatecholamine Contents of Different Region of Adult Rat Brain Are Altered Following Short and Long-term Exposures to Pb+2
Catecholamine is a group of neurotransmitters that is believed to be responsible for the normal function of animal brain. Physiological and behavioral changes of human body have been reported due to the damage of the brain function following lead exposure. Due to the assumption of lead disposal in brain tissue with two year for its half-life, which results in alteration of brain function, we in...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2015