Observations upon the Noguchi Modification of the Wassermann Complement Fixation Test in the Diagnosis of Lues in the Military Service
نویسنده
چکیده
In the vast majority of cases examined in this laboratory the result of the Wassermann test was simply confirmatory of the clinical findings, but there were numerous suspicious cases, or cases in which symptoms were present and the patient denied a specific history, in which the test was of the greatest value, and it is in such instances, perhaps, that it may be regarded as "the court of last resort " in arriving at a conclusion regarding the nature of the condition present. Certainly if there is any value in experience and statistics, we are justified in regarding this test as the most valuable means we possess of diagnosing lues, and our experience with the Noguchi modification of the test has justified all that has been claimed for that method. We believe that our results have proven that by the use of the complement fixation test in the military service it is possible to prevent the enlistment of men suffering from latent lues who would otherwise be enlisted; to control specific treatment by using it as an index of the efficiency of such treatment; to clear up the diagnosis of obscure or suspicious cases; and to enable the surgeon to avoid mistakes in discharges for disability in cases suspected of this disease. Owing to the facility with which clinical observations can be made in armies, and the control that is possible of tested individuals, it is to be hoped that the Noguchi modification of the complement fixation test will be more widely used than it has been in the military services, for which we believe it is especially adapted. So far as we are aware the Medical Department of our army is the first to adopt this test as a routine diagnostic procedure and to apply it in the case of applicants for enlistment.
منابع مشابه
The Relation of Certain Bacteria to Non-specific Reactions with the Complement Fixation Test for Lues
Several investigators who have had a large experience with the complement fixation test for lues have called attention to the development in sera of anticomplementary bodies which cause inhibition of hemolysis in both the antigen and control tubes, and they have found that in most instances this property of the serum is lost after heating it for half an hour at 560 C. In some instances, however...
متن کاملA Study of Complement Fixation in Syphilis with Spirochæta Culture Antigens
It is our purpose in this communication to give the results of some work upon complement fixation in syphilitic and other sera, using specific antigens prepared from pure cultures of Spirochceta pallida, Spirochceta pertenuis, and Spirochceta microdentia. The results are compared with those obtained with the same sera and a stock antigen used in our routine Wassermann tests, this antigen consis...
متن کاملTurnover Intention of Nurses Working in the Selected Military Hospitals in Tehran
Introduction: Nurses play crucial roles in the health system, but their intention to leave service is one of the biggest challenges of today’s life. There has been a plenty of research emphasizing on the effect of leadership upon the creation of such a phenomenon. Objective: The present study aimed to investigate the role of training the transformational leadership approach presented to head nu...
متن کاملObservations on the Wassermann Reaction
The Wassermann reaction carried out according to the method of McIntosh and Fildes, with cholesterolized antigen and with certain allowances for the presence of native anti-sheep amboceptor; leads to about the same result as when it is done according to the recent proposal of Noguchi, with the native human complement and acetone-insoluble lipoids as antigen. The differences are such as to sugge...
متن کاملComplement Deviation in Scarlet Fever with Comparative Studies of the Wassermann and Noguchi Systems
The Wassermann reaction in scarlet fever per se is uniformly negative. The antigen of scarlet fever liver yields practically the same results as that of luetic liver, and both fail to deviate complement with scarlet fever antibodies. The Noguchi reaction in scarlet fever is practically negative. Sixteen cases, or 6.4 per cent. of 250 cases, were positive when active serum was used; with inactiv...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Journal of Experimental Medicine
دوره 12 شماره
صفحات -
تاریخ انتشار 2003