Clinical value of fluid bolus contrast flow meter during hysterosalpingography.

نویسندگان

  • Y P Ji
  • Y Xu
  • S Z Xia
  • F Y Bian
  • H Zhang
  • G H Shen
چکیده

The purpose of this study was to investigate the clinical value of the fluid bolus contrast flow meter during hysterosalpingography. Hysterosalpingography information of 342 cases, which included a manual handset group of 213 cases and a bolus instrument group of 129 cases were reviewed. Comparative analysis was used to compare the two groups in order to assess the clinical adverse reactions, contrast agent reflux, and image quality. In the instrument bolus group compared with the manual handset group, the clinical adverse reactions decreased from 75.12 to 31.78% (P < 0.001); the backflow phenomenon of the contrast agent decreased from 13.62 to 3.10% (P < 0.01); and image quality significantly improved, with the A class film rate increasing from 54.46 to 68.99% (P < 0.01) and the C class film rate decreasing from 8.92 to 2.33% (P < 0.05). The use of a contrast bolus through the liquid inlet of the hysterosalpingography instrument can provide fully dynamic observation, reducing the contrast agent reflux and adverse reactions as well as improving the image quality and diagnostic accuracy. In addition, the medical staff is not subjected to radiographic radiation. Therefore, it is a safe and reliable imaging method.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Influence of Nanoparticles Phenomena on the Peristaltic Flow of Pseudoplastic Fluid in an Inclined Asymmetric Channel with Different Wave Forms

The influence of nanofluid with different wave forms in the presence of inclined asymmetric channel on peristaltic transport of a pseudoplastic fluid is examined. The governing equations for two dimensional and two directional flows of a pseudoplastic fluid along with nanofluid are modeled and then simplified under the assumptions of long wavelength and low Reynolds number approximation. The ex...

متن کامل

Influence of coronary flow profiles on bolus shape and quantitative myocardial perfusion MRI

Simulations of the influence of contrast agent bolus dispersion on the shape of the contrast agent bolus and on quantification of myocardial blood flow (MBF) have been made using an exponential residue function model, and an computational fluid dynamics (CFD) approach. Based on the exponential residue function model, up to 20% underestimation of MBF appeared reasonable. CFD simulations showed t...

متن کامل

P-209: The Value of Hysterosalpingography in the Diagnosis of Tubal Pathology Among in Infertile Patients

Background: Infertility, defined by the failure to achieve a clinical pregnancy after twelve months or more of regular unprotected sexual intercourse. infertility is an important health problem in the society .tubal pathology is one of the main causes of infertility.it is estimated to account for 12-33%.hysterosalpingography is a method used for screening purposes in the routine infertility eva...

متن کامل

Oral fluid therapy. A promising treatment for vasodepressor syncope.

OBJECTIVE To investigate the predictive value of an intravenous fluid bolus during tilt table testing on clinical outcome and to evaluate of oral therapy is an effective treatment for patients with vasodepressor syncope. DESIGN Retrospective cohort. SETTING Regional pediatric cardiology outpatient clinic. PATIENTS Patients (N = 58) with a positive baseline tilt table testing result who we...

متن کامل

Computational Fluid Dynamics Simulations of Contrast Agent Bolus Dispersion in a Coronary Bifurcation: Impact on MRI-Based Quantification of Myocardial Perfusion

Contrast-enhanced first-pass magnetic resonance imaging (MRI) in combination with a tracer kinetic model, for example, MMID4, can be used to determine myocardial blood flow (MBF) and myocardial perfusion reserve (MPR). Typically, the arterial input function (AIF) required for this methodology is estimated from the left ventricle (LV). Dispersion of the contrast agent bolus might occur between t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Genetics and molecular research : GMR

دوره 14 1  شماره 

صفحات  -

تاریخ انتشار 2015