A quality control program for MR‐guided focused ultrasound ablation therapy

نویسندگان

  • Tao Wu
  • Joel P. Felmlee
چکیده

In this study, we propose a quality control program for MR-guided focused ultrasound (FUS) ablation treatment to assess FUS beam positioning accuracy, FUS power delivery accuracy, MR imaging quality, and FUS ablation system safety. A total of 353 sonication points in Lucite cards were measured, the average placement errors were -0.06 mm in the SI direction and -0.04 mm in the LR direction. Temperature elevation was calculated from MR phase difference images and the measured water proton chemical shift (WPCS) temperature coefficient. WPCS temperature calibration for phantoms yielded a temperature coefficient of 0.011 ppm/degree C. Sixteen experiments were conducted using six different phantoms to test the reliability of FUS power delivery. SNR and RF power calculated from phantom images were analyzed and stored at the MR console. A computer program was developed to integrate the system power delivery and the MR image quality control into one automated process. In the clinical trial at our institution, we expect this quality control program to be carried out before each patient treatment. If measured quality control values exceeds or below the preset values, a system service and retest should be conducted before the treatment.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

PET and MRI-guided focused ultrasound surgery for hypoxic-tissue ablation combined with radiotherapy in solid tumors

Background: The rationale was to develop an ablation approach to destroy regions of tumor resistant to radiation and thus reduce the time required for whole tumor ablation, while improving overall tumor control after radiotherapy. Materials and Methods: The system is composed of a micro positron emission tomography (mPET), 7T magnetic resonance imaging (MRI), and a customized MRI-compatible foc...

متن کامل

Optimization of volumetric MR-guided high-intensity focused ulatrsound ablations in moving organs

Introduction In this work, a method for the optimization of volumetric MR-guided high intensity focused ultrasound (HIFU) ablations is presented. While commonly MRguidance of thermal therapies is based on temperature control the on-line assessment of the thermal dose has been suggested to determine the therapy endpoint [1]. Therefore, we propose to monitor the thermal dose [2] of the treated ti...

متن کامل

Sonalleve MR-HIFU with DISC Philips MR-guided High Intensity Focused Ultrasound with Direct Skin Cooling

High Intensity Focused Ultrasound guided by Magnetic Resonance Imaging (also known as MR-guided HIFU, MRgHIFU, or MRgFUS) is a therapy technique which uses focused ultrasound waves to heat and coagulate tissue deep inside the body without damaging intervening tissue and offers an novel, non-invasive treatment option for solid tumors. The Philips Sonalleve MR-HIFU system, initially released in 2...

متن کامل

First non-invasive thermal ablation of a brain tumor with MR guided focused ultrasound

Magnetic resonance-guided focused ultrasound surgery (MRgFUS) allows for precise thermal ablation of target tissues. While this emerging modality is increasingly used for the treatment of various types of extracranial soft tissue tumors, it has only recently been acknowledged as a modality for noninvasive neurosurgery. MRgFUS has been particularly successful for functional neurosurgery, whereas...

متن کامل

The relationship of T2WI signal intensity of uterine fibroids and the temperature curve in MR-guided high-intensity focused ultrasound (HIFU) ablation

Background/introduction MR guided high-intensity focused ultrasound (HIFU) ablation is increasingly being used worldwide to treat symptomatic uterine fibroids because of its excellent therapeutic efficacy in controlling symptoms and its excellent safety record. High signal intensity on T2WI MR images of fibroids is firstly considered a factor that induces poor ablation outcomes. Nevertheless, t...