Biomechanical aspects of primary implant stability: a human cadaver study.

نویسندگان

  • Ilser Turkyilmaz
  • Lars Sennerby
  • Edwin A McGlumphy
  • Tolga F Tözüm
چکیده

BACKGROUND The quality of bone is an important factor in the successful implant treatment, and it is evident that higher implant failure is more likely in poor quality of bone. The primary stability of oral implants related to resistance to micromotion during healing is influenced by bone quality, surgical technique, and implant design. PURPOSES The aims of this biomechanical study were to explore the effect of bone quality on initial intraosseous stability of implants, and to determine the correlations between the bone quality and implant stability parameters. MATERIALS AND METHODS Twenty-four implants (Neoss Ltd., Mölnlycke, Sweden) were placed into anterior and posterior regions of three human cadaver mandibles. The bone densities of implant recipient sites were preoperatively determined using computerized tomography (CT) in Hounsfield unit (HU). The maximum insertion torque values were recorded, and primary implant stability measurements were noninvasively performed by means of resonance frequency analysis (RFA). RESULTS The bone density values ranged from -267 HU to 553 HU. It was found that mean bone density, insertion torque, and RFA values were 113 +/- 270 HU, 41.9 +/- 5 Ncm, and 70 +/- 7 implant stability quotient (ISQ), respectively. Statistically significant correlations were found between bone density and insertion torque values (r = 0.690, p < .001); bone density and ISQ values (r = 0.557, p < .05); and insertion torque and ISQ values (r = 0.853, p < .001). CONCLUSION CT is a useful tool to assess bone quantity and quality in implant recipient sites, and bone density has a prevailing effect on implant stability at placement.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

THE EFFECTS OF ANTERIOR DISCECTOMY AND INTERPOSITION AL IMPLANT UPON LUMBAR MOTION SEGMENT STABILITY

The cadaver spine motion segment behavior under torsional load was evaluated with the disc intact, with partial anterior discectomy and with spacer insertion. The results of this study explain how anterior lumbar discectomy and interbody fusion (ALIF) affects the torsional stability of the motion segment. The pseudarthrosis rate of the anterior lumbar discectomy and interbody fusion (ALIF)...

متن کامل

Femoral component revision using impacted morsellised cancellous graft. A biomechanical study of implant stability.

We have tested the axial and torsional stability of femoral components after revision arthroplasty in a cadaver model, using impacted morsellised cancellous graft and cement. Each one of six matched pairs of fresh frozen human femora had either a primary or a revision prosthesis cemented in place. For the 'revision' experiments, all cancellous bone was removed from the proximal femur which was ...

متن کامل

Assessing the Acetabular Cup Implant Primary Stability by Impact Analyses: A Cadaveric Study

BACKGROUND The primary stability of the acetabular cup (AC) implant is an important determinant for the long term success of cementless hip surgery. However, it remains difficult to assess the AC implant stability due to the complex nature of the bone-implant interface. A compromise should be found when inserting the AC implant in order to obtain a sufficient implant stability without risking b...

متن کامل

Differences in the mechanical properties of calcaneal artificial specimens, fresh frozen specimens, and embalmed specimens in experimental testing.

BACKGROUND Artificial calcanei, fresh-frozen cadaver specimens, and embalmed cadaver specimens were compared in experimental testing under biocompatible loading to clarify the biocompatibility of artificial calcaneal specimens for implant testing. METHODS Two different artificial calcaneal bone models (Sawbone, Pacific Research Laboratories, Vashon, WA, and Synbone, Synbone Inc., Davos, Switz...

متن کامل

Evidence Based Development of a Novel Lateral Fibula Plate (VariAx Fibula) Using a Real CT Bone Data Based Optimization Process During Device Development

Development of novel implants in orthopaedic trauma surgery is based on limited datasets of cadaver trials or artificial bone models. A method has been developed whereby implants can be constructed in an evidence based method founded on a large anatomic database consisting of more than 2.000 datasets of bones extracted from CT scans. The aim of this study was the development and clinical applic...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical implant dentistry and related research

دوره 11 2  شماره 

صفحات  -

تاریخ انتشار 2009