Electrical impedance tomography (EIT) is a promising medical imaging technique which could aid differentiation of haemorrhagic from ischaemic stroke in an ambulance. One challenge in EIT is the ill-posed nature of the image reconstruction, i.e., that small measurement or modelling errors can result in large image artefacts. It is therefore important that reconstruction algorithms are improved with regard to stability to modelling errors. We identify that wrongly modelled electrode positions constitute one of the biggest sources of image artefacts in head EIT. Therefore, the use of the Fréchet derivative on the electrode boundaries in a realistic three-dimensional head model is investigated, in order to reconstruct electrode movements simultaneously to conductivity changes. We show a fast implementation and analyse the performance of electrode position reconstructions in time-difference and absolute imaging for simulated and experimental voltages. Reconstructing the electrode positions and conductivities simultaneously increased the image quality significantly in the presence of electrode movement.
منابع مشابه
Correction of electrode modelling errors in multi-frequency EIT imaging.
The differentiation of haemorrhagic from ischaemic stroke using electrical impedance tomography (EIT) requires measurements at multiple frequencies, since the general lack of healthy measurements on the same patient excludes time-difference imaging methods. It has previously been shown that the inaccurate modelling of electrodes constitutes one of the largest sources of image artefacts in non-l...
متن کاملSensitivity Distribution Simulations of Impedance Tomography Electrode Combinations
As reconstruction techniques generating images in electrical impedance tomography (EIT) are sensitive to noise, small errors on measured data can result into large errors in final images. In order to optimize the signal acquisition from any region, measurement should possess highest sensitivity and selectivity in that region. This study was conducted to estimate measurement properties of variou...
متن کاملStroke type differentiation using spectrally constrained multifrequency EIT: evaluation of feasibility in a realistic head model.
We investigate the application of multifrequency electrical impedance tomography (MFEIT) to imaging the brain in stroke patients. The use of MFEIT could enable early diagnosis and thrombolysis of ischaemic stroke, and therefore improve the outcome of treatment. Recent advances in the imaging methodology suggest that the use of spectral constraints could allow for the reconstruction of a one-sho...
متن کاملEffective electrode positions and stimulation patterns for head EIT
The objective of this study is to find an effective stimulation and measurement strategy to improve distinguishability for head EIT. To better understand the relationship between distinguishability and various strategies (stimulation/measurement patterns) for a set of electrodes, we evaluated a realistic head model and a range of common strategies.
متن کاملValidation of a 3D reconstruction algorithm for EIT of human brain function in a realistic head-shaped tank.
Previous work has demonstrated that electrical impedance tomography can be used to image human brain activity during evoked responses, but two-thirds of the reconstructed images fail to localize an impedance change to the expected stimulated cortical area. The localization failure may be caused by modelling the head as a homogenous sphere in the reconstruction algorithm. This assumption may lea...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Physiological measurement
دوره 36 12 شماره
صفحات -
تاریخ انتشار 2015