Guidewire catheter change in central venous catheter biofilm formation in a burn population.
نویسندگان
چکیده
This study was designed to assess the risk of colonization and biofilm formation of central venous catheters left in situ for seven days vs those changed over a guidewire at three days and removed at seven days. Colonization was determined using scanning and transmission electron microscopy and compared to a special scraping/sonication culture method. Thirty-one catheters were examined, and no difference was found between catheters left in situ (9 of 16 colonized) and those changed over a guidewire (11 of 15 colonized). Colonization rates rose significantly from 4 of 15 catheters at the time of guidewire change to 11 of 15 at 7 days (p less than 0.001). Of the catheters defined as colonized by SEM, the special culture technique showed bacterial growth in only 35 percent, making a negative culture result of dubious value in ruling out catheter colonization. No beneficial effect of guidewire changes in reducing colonization could be demonstrated.
منابع مشابه
Comparing the anatomy of the intrathoracic systemic central venous system in Iranian pediatrics and adults based on chest CT scan and evaluation of rate of catheter malposition in children
Background: Central venous catheterization is a procedure that is being performed frequently especially in critical clinical settings. In such conditions, good knowledge of the surface anatomy of venous structures is vital to avoid possible complications which could result in life-threatening situations such as bleeding and pneumothorax. Considering the difference between venous anatomy of chil...
متن کاملThe ability of uropathogenic Escherichia coli isolates in biofilm formation on urinary catheter and association with bcsA and draE genes
The product biofilm by E.coli strain can cause serious problem for human health. Catheter is considered to be s suitable place for colonization of microorganisms, so that in %5-10 of patients who used catheter for only one day and also in all patients who used it for over 28 days, this colonization of bacteria is observed on catheter. This study is come out in order to compare biofilm formation...
متن کاملUltrasound detection of guidewire position during central venous catheterization.
INTRODUCTION Ultrasound guidance decreases complications of central venous catheter (CVC) placement, but risks of arterial puncture and inadvertent arterial catheter placement exist. Ultrasound-assisted detection of guidewire position in the internal jugular vein could predict correct catheter position before dilation and catheter placement. METHODS Ultrasound examinations were performed in a...
متن کاملGuidewire-Related Complications during Central Venous Catheter Placement: A Case Report and Review of the Literature
Seldinger's technique is widely used to place central venous and arterial catheters and is generally considered safe. The technique does have multiple potential risks. Guidewire-related complications are rare but potentially serious. We describe a case of a lost guidewire during central venous catheter insertion followed by a review of the literature of this topic. Measures which can be taken t...
متن کاملCentral venous catheter replacement strategies: a systematic review of the literature.
OBJECTIVE To evaluate the effect of guidewire exchange and new-site replacement strategies on the frequency of catheter colonization and infection, catheter-related bacteremia, and mechanical complications in critically ill patients. DATA SOURCES We searched for published and unpublished research by means of MEDLINE and Science Citation Index, manual searching of Index Medicus, citation revie...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Chest
دوره 100 4 شماره
صفحات -
تاریخ انتشار 1991