Fiberoptic intubation: troubles with the "Tube"?

نویسندگان

  • Melissa Wheeler
  • Richard M Dsida
چکیده

To the Editor:—Dr. Kristensen has concluded that during intubation with the use of a flexible fiberscope, the use of the Parker Flex-Tube results in a significantly lower rate of repositioning and repeated attempts at passing the tube into the trachea, compared to a standard endotracheal tube. We believe it would be more appropriate to conclude that the Parker tube is better only when the standard tube is improperly oriented during passage. Dr. Kristensen reported that once the standard tube was rotated counterclockwise by 90 degrees, its success rate improved to 26 out of 38 attempts. This was essentially the same as the success rate (27 out of 38 attempts) of the Parker tube and is consistent with our experience with the standard tube. Why not simply start with the standard tube rotated counterclockwise by 90 degrees? The Parker tube requires a higher cuff pressure, which, in our opinion, makes it less desirable. The simple technique of rotating the standard tube counterclockwise by 90 degrees during the first attempt along a fiberoptic bronchoscope has been our standard practice for years, thanks to a suggestion by Katsnelson et al. in 1992. Eighteen years ago, Cossham proposed rotating a standard tube counterclockwise by 90 degrees to facilitate passage along a gum-elastic bougie, and in 1990, Dogra et al. demonstrated convincingly the usefulness of this technique. Granted, this technique may not be widely appreciated, perhaps because the gum-elastic bougie is not used in some parts of the world and the use of fiberoptic bronchoscopy is infrequent. As such, Dr. Kristensens’study should help to popularize this important “trick.”

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measuring incisor-carina distance by fiberoptic bronchoscopy to guide the placement of a left-sided double-lumen endobronchial tube

The aim of this randomized observational study was to evaluate the effect of measuring the incisor-carina distance by fiberoptic bronchoscopy in guiding the placement of a left-sided double-lumen endobronchial tube. Fifty patients (American Society of Anesthesiologists class I-II) undergoing elective thoracic procedures requiring single-lung ventilation using a left-sided double-lumen endobronc...

متن کامل

[Difficult fiberoptic tracheal intubation in 1 month-old infant with Treacher Collins Syndrome].

Neonates and small infants with craniofacial malformation may be very difficult or impossible to mask ventilate or intubate. We would like to report the fiberoptic intubation of a small infant with Treacher Collins Syndrome using the technique described by Ellis et al. CASE REPORT An one month-old infant with Treacher Collins Syndrome was scheduled for mandibular surgery under general endotra...

متن کامل

Endotracheal Intubation with Flexible Fiberoptic Bronchoscope (FFB) in Cases of Difficult Airway

Endotracheal intubation is a procedure whereby a tube is inserted into the trachea to warrant and maintain adequate ventilation with good respiratory gas exchange in patients who undergo anesthesia for surgery or require invasive mechanical ventilation.Since 1967 the flexible fiberoptic bronchoscope was considered as an advanced device to intubate patients with difficult airway having surgery,“...

متن کامل

Case Report Experience of awake Fiberoptic Nasotracheal Intubation in an elderly Patient with Tonsil Cancer

Awake intubation with fiberoptic bronchoscopy (FOB) is a popular technique in patients with difficult intubation criteria. Preservation of spontaneous respiration by nasotracheal intubation with FOB accompanied by sedation was performed in a case assessed as difficult intubation due to a high Mallampati score at preoperative evaluation and the presence of a mass extending to the oral cavity. Fo...

متن کامل

Usefulness of a Cook® airway exchange catheter in laryngeal mask airway-guided fiberoptic intubation in a neonate with Pierre Robin syndrome -A case report-

The case of a 33-day-old boy with Pierre Robin syndrome using a Cook® airway exchange catheter in laryngeal mask airway-guided fiberoptic intubation is presented. After induction with sevoflurane, classical reusable laryngeal mask airway (LMA) #1 was inserted and ultrathin fiberoptic bronchoscope (FOB) was passed through. A Cook® airway exchange catheter (1.6 mm ID, 2.7 mm OD) was passed throug...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Anesthesiology

دوره 99 5  شماره 

صفحات  -

تاریخ انتشار 2003