Pressure and Flow Characteristics of a Novel Bidirectional Cannula for Cardiopulmonary Bypass

نویسندگان

  • Yi Chen
  • Elli Tutungi
  • James McMillan
  • Sara M. Tayeh
  • Jess K. Underwood
  • Adam C. Wells
  • Julian A. Smith
  • Randall A. Moshinsky
چکیده

OBJECTIVE Femoral arterial cannulation is associated with a significant risk of lower limb ischemia. The aim of the study was to assess the pressure and flow in the femoral artery using a novel bidirectional femoral cannula in a sheep model of peripheral cardiopulmonary bypass. METHODS Peripheral cardiopulmonary bypass was established using a multistage venous cannula inserted into the internal jugular vein and the bidirectional or a conventional arterial cannula into the femoral artery in seven adult ewes. Systemic and distal perfusion pressures and flow rates were measured during cardiopulmonary bypass with flow rates of 1, 2, 3, and 4 L/min. Lower limb venous oxygen saturation and lactate levels were also measured. RESULTS A significantly higher blood flow in the lower limb using the bidirectional cannula was observed and compared with a conventional cannula at all flow rates (mean flow 115 mL/min vs 10 mL/min, P < 0.05). The mean distal perfusion pressure was also significantly higher in the bidirectional cannula group (86 mm Hg vs 45 mm Hg at 4 L/min of flow, P < 0.05). The bidirectional cannula was associated with higher venous oxygen saturations in the lower limb than in the conventional cannula group; however, lower limb lactate production was similar in the two groups. CONCLUSIONS This in vivo data demonstrates superior distal flow and pressure characteristics of a novel bidirectional cannula compared with a conventional femoral cannula during peripheral cardiopulmonary bypass.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Placement of a modified cannula in the innominate vein for sufficient drainage during the bidirectional Glenn shunt procedure without cardiopulmonary bypass

During the bidirectional Glenn shunt procedure in small infants, the standard right-angle venous cannula is frequently placed in the innominate vein for establishing the temporary veno-atrial bypass without cardiopulmonary bypass, but it should be small enough to allow flow to pass around it from the internal jugular vein opposite to the side the cannula is directed. Small cannula may induce th...

متن کامل

Improved hydrodynamics of a new aortic cannula with a novel tip design.

BACKGROUND Reduction of atheroembolic complications during cardiopulmonary bypass remains a major challenge in cardiac surgery. New cannula tip designs may help to attenuate this problem by improved hydrodynamics. METHODS Pressure gradients and back pressures of a new aortic cannula tip design were measured and compared with the Medos X-Flow, Sarns Soft-Flow and Argyle THI cannulae at various...

متن کامل

Novel emboli protection cannula during cardiac surgery: first animal study.

BACKGROUND Stroke after open heart surgery is a major cause of morbidity and mortality. Up to 60% of intraoperative cerebral events are caused by emboli generated by manipulations of the aorta during surgery. This is the first animal study evaluating the safety and efficacy of a novel aortic cannula designed to extract solid and gaseous emboli during cardiac surgery. METHODS Seven domestic pi...

متن کامل

Venous cannula performance assessment in a realistic caval tree model.

OBJECTIVES A new caval tree system was designed for realistic in vitro simulation. The objective of our study was to assess cannula performance for virtually wall-less versus standard percutaneous thin-walled venous cannulas in a setting of venous collapse in case of negative pressure. METHODS For a collapsible caval model, a very flexible plastic material was selected, and a model with nine ...

متن کامل

Numerical simulation of left ventricular assist device implantations: comparing the ascending and the descending aorta cannulations.

In this work we present numerical simulations of continuous flow left ventricle assist device implantation with the aim of comparing difference in flow rates and pressure patterns depending on the location of the anastomosis and the rotational speed of the device. Despite the fact that the descending aorta anastomosis approach is less invasive, since it does not require a sternotomy and a cardi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017