Clinical outcomes after implantation of a centrifugal flow left ventricular assist device and concurrent cardiac valve procedures.

نویسندگان

  • Carmelo Milano
  • Francis D Pagani
  • Mark S Slaughter
  • Duc Thinh Pham
  • David R Hathaway
  • Mary V Jacoski
  • Kevin B Najarian
  • Keith D Aaronson
چکیده

BACKGROUND Cardiac valve procedures are commonly performed concurrently during implantation of left ventricular assist devices, but the added procedural risk has not been studied in detail. METHODS AND RESULTS Data from patients receiving the HeartWare Ventricular Assist Device in the ADVANCE bridge to transplant (BTT) trial and continued access protocol were reviewed. Of 382 consecutive patients who completed follow-up between August 2008 and June 2013 (mean time on support 389 days, median 271 days), 262 (68.6%) underwent isolated HeartWare Ventricular Assist Device implantation, 75 (19.6%) a concurrent valve procedure, and 45 (11.8%) concurrent nonvalvular procedures. Of the concurrent valve procedures, 56 were tricuspid, 13 aortic, and 6 mitral. Survival was similar between groups (79% for concurrent valve procedures and 85% for HeartWare Ventricular Assist Device only at 1 year; P=0.33). Concurrent valve procedures were also associated with increased unadjusted early right heart failure (RHF). A multivariable analysis for death and RHF (121 total events) identified female sex (odds ratio=2.0 [95% confidence interval, 1.2-3.3; P=0.0053]) and preimplant tricuspid regurgitation severity (odds ratio=2.9 [95% confidence interval, 1.8-4.8, P<0.0001]) as independent predictors while concurrent tricuspid valve procedures (TVP) were not predictors. Furthermore, patients with significant preimplant tricuspid regurgitation who did not receive a TVP experienced an increased rate of late RHF compared with those who received TVP (0.19 versus 0.05 events per patient-year, respectively; P=0.024). CONCLUSIONS Compared with HeartWare Ventricular Assist Device alone, survival was equivalent for the concurrent valve procedure group. Tricuspid regurgitation severity was the most important predictor of increased postoperative RHF, and concurrent TVP was not an independent predictor of RHF overall. Concurrent TVP may reduce the rate of late RHF for patients with significant preimplant tricuspid insufficiency. CLINICAL TRIAL REGISTRATION URL http://www.clinicaltrials.gov. Unique identifier: NCT00751972.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Low operative mortality with implantation of a continuous-flow left ventricular assist device and impact of concurrent cardiac procedures.

BACKGROUND The objective of this study was to determine the impact of concurrent cardiac procedures (CCP) on patient outcomes after HeartMate II (HMII) left ventricular assist device implantation. METHODS AND RESULTS Two hundred eighty-one patients underwent implantation of a HMII as a bridge to transplantation from March 2005 to March 2007. One hundred seventy patients had an HMII implanted ...

متن کامل

Application of centrifugal pump in right ventricular failure due to pulmonary artery hypertension. (A case report)

Background: It has not been yet developed a ost suitable method to treat right ventricular failure due to pulmonar artery hypertention resulted from ventricular arrhythia. Though some case reports about patients ready to heart transplant using left assist device or biventral assist device as bridge have been published in Journals, but nocase concerning application of centrifugal pump for treatm...

متن کامل

What’s New in MCS

Right ventricular dysfunction and significant tricuspid regurgitation are frequently seen in end stage heart failure patients undergoing Left Ventricular Assist Device (LVAD) implantation. Clinical impact of tricuspid valve repair at the time of LVAD implantation in patients with pre-existing significant tricuspid regurgitation has been a topic of debate for several years. Some groups have advo...

متن کامل

Design an Equivalent Left Ventricular Assist Device for Medical Equipment Labs

LVAD is a mechanical pump supporting a weak heart function and blood flow. Sometimes, the heart may not recover fast enough to take over the pumping action immediately after surgery, in such patients a temporary support device has been employed to maintain the pumping action until the patient’s own heart recovers. This device can be considered as a temporary alternative before the process of ar...

متن کامل

Mechanical circulatory support for right ventricular failure.

OBJECTIVES The aim of this study was to explore the clinical utility of a commercially available centrifugal flow pump as a centrifugal flow-right ventricular support device (CF-RVSD) in patients with right ventricular failure (RVF). BACKGROUND RVF is associated with high in-hospital mortality. Limited data regarding efficacy of the CF-RVSD for RVF exist. METHODS We retrospectively reviewed...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 130 11 Suppl 1  شماره 

صفحات  -