چکیده

The ZoMaxx Coronary Stent System elutes the antiproliferative agent zotarolimus via a biocompatible phosphorylcholine polymer loaded onto a novel, thin, stainless steel stent platform containing an 0.0007-inch inner layer of tantalum that enhances fluoroscopic radiopacity. The objective of this single-arm prospective clinical trial was to assess the safety and performance of the ZoMaxx stent for the treatment of coronary artery stenosis. Forty consecutive patients with ischemic coronary occlusive disease due to single de novo obstructive lesions of native coronary arteries were treated with 3 x 18 mm ZoMaxx stents at the Dante Pazzanese de Cardiologie in Saõ Paulo, Brazil, between April and July 2005. Independent core laboratories analyzed quantitative coronary angiography and intravascular ultrasound results immediately after stent implantation, and after 4 months. The lesion, procedure, and device-deployment success rates were all 100% (40 of 40). There were no major adverse cardiac events during the study. Follow-up quantitative coronary angiography at 4 months revealed in-stent and in-segment late lumen losses of 0.20 +/- 0.35 and 0.17 +/- 0.35 mm, respectively. Follow-up intravascular ultrasound at 4 months revealed 6.5 +/- 6.2% neointimal volume obstruction. There were no instances of late acquired stent incomplete apposition or stent thrombosis. In conclusion, the ZoMaxx Coronary Stent can be safely implanted for the treatment of de novo coronary artery stenosis. The inhibition of neointima formation as measured by follow-up angiography and IVUS after 4 months suggests therapeutic potential for the reduction of restenosis.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Quest for the Perfect Stent for a Given Patient: Drug-Coated Stents for the Treatment of Coronary Disease.

S ince the initial case of plain old balloon angioplasty by Andreas Grüntzig in 1977, there has been tremendous advancement in the treatment of coronary artery disease. After balloons and bare-metal stents (BMS), the introduction of drugeluting stents (DES) in 2002 transformed the practice of percutaneous coronary intervention (PCI) by significantly reducing rates of restenosis and repeat revas...

متن کامل

Comparison of 12-Month Outcomes with Zotarolimus- and Paclitaxel-Eluting Stents: A Meta-Analysis

Revascularization after myocardial infarction is often achieved via percutaneous coronary intervention, which often entails stenting. Drug-eluting stents have shown benefits over bare metal stents in this setting, and a variety of drug-eluting stents are now available, including sirolimus-, paclitaxel-, and zotarolimus-eluting stents. There are studies that have compared the various drug-elutin...

متن کامل

Sirolimus-Versus Zotarolimus-Eluting Stents in Acute Coronary Syndromes With C Type Left Anterior Descending Artery Lesions: A Three-Year Clinical Follow-Up

BACKGROUND Drug-eluting stents have improved the efficacy of percutaneous coronary intervention and made it the preferred therapy in the treatment of ischemic heart diseases including acute coronary syndromes. The objective of the study was to compare the clinical efficacy and safety of sirolimus-eluting stent with that of zotarolimus-eluting stent following percutaneous coronary intervention f...

متن کامل

Randomized, double-blind, multicenter study of the Endeavor zotarolimus-eluting phosphorylcholine-encapsulated stent for treatment of native coronary artery lesions: clinical and angiographic results of the ENDEAVOR II trial.

BACKGROUND The use of the Endeavor stent might reduce restenosis and stent thrombosis at 9 months. METHODS AND RESULTS Patients (n = 1197) treated for single coronary artery stenosis were enrolled in a prospective, randomized, double-blind study and randomly assigned to receive the Endeavor zotarolimus-eluting phosphorylcholine polymer-coated stent (n = 598) or the same bare metal stent but w...

متن کامل

Comparison of titanium-nitride-oxide-coated stents with zotarolimus-eluting stents for coronary revascularization a randomized controlled trial.

OBJECTIVES This study sought to compare the efficacy of passive stent coating with titanium-nitride-oxide (TiNO) with drug-eluting stents releasing zotarolimus (ZES) (Endeavor, Medtronic, Minneapolis, Minnesota). BACKGROUND Stent coating with TiNO has been shown to reduce restenosis compared with bare-metal stents in experimental and clinical studies. METHODS In an assessor-blind noninferio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The American journal of cardiology

دوره 99 10  شماره 

صفحات  -

تاریخ انتشار 2007