Crystalline Silica Analysis: A Comparison of Calibration Materials and Recent Coal Mine Dust Size Distributions

نویسنده

  • Steven J. Page
چکیده

Since 1982 standard calibration materials recommended for respirable crystalline silica analysis by the Mine Safety and Health Administration (MSHA) P7 Infrared Method and the National Institute for Occupational Safety and Health (NIOSH) X-ray Diffraction (XRD) Analytical Method 7500 have undergone minor changes in size distribution. However, a critical assumption has been made that the crystalline silica in ambient mine atmosphere respirable dust samples has also remained essentially unchanged in particle size distribution. The objective of this work, therefore, is to compare recent particle size distributions of underground coal mine dust and the silica component of these dusts with estimated aerodynamic particle size distributions of calibration standard materials MIN-U-SIL 5, Berkeley 5, and SRM 1878 used by two crystalline silica analysis techniques. This work provides resolution to a previously reported discrepancy involving the proper sample dilution for the particle sizing method used. Dust impactor sampling data for various locations in 13 underground coal mines were collected between 1991 and 1998 and analyzed for the respirable mass median aerodynamic diameters. The data suggest that the MSHA P7 Method will underestimate the silica content of the sample by at most 8.5 % in the median size range of 0.9–3.6 μm and that it is unlikely one would obtain any significant error in the MSHA P7 Method analysis when the method uses Berkeley 5, MIN-U-SIL 5, or SRM 1878 as a calibration standard material. The results suggest that the NIOSH Analytical Method 7500 would be more appropriate for a dust sample that is representative of the total (no cyclone classifier) rather than the respirable airborne dust, particularly since the mass fraction in the size range below 4 μm is usually a small percentage of the total airborne dust mass. However, the NIOSH Analytical Method 7500 is likely to underestimate the silica content of an airborne respirable dust sample by only 5–10 %. The results of this study also suggest that any changes that may have occurred in the median respirable size of airborne coal mine dust are not significant enough to cause any appreciable error in the current methods used for respirable crystalline

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Toxicity and occupational health hazards of coal fly ash (CFA). A review of data and comparison to coal mine dust.

Coal fly ashes (CFA) are complex particles of a variable composition, which is mainly dependent on the combustion process, the source of coal and the precipitation technique. Toxic constituents in these particles are considered to be metals, polycyclic aromatic hydrocarbons and silica. The purpose of this review was to study the in vitro and in vivo data on coal fly ash and relate the studied e...

متن کامل

Exposure to silica dust on continuous mining operations using flooded-bed scrubbers.

Silicosis, a debilitating and potentially deadly lung disease, develops through inhalation of excessive concentrations of respirable crystalline silica dust. In underground coal mines, continuous miner operators have a high risk of overexposure to silica, with approximately 25% of compliance dust samples exceeding the permissible exposure limit. Continuous miners often extract high-silica-conte...

متن کامل

Respiratory disease mortality among US coal miners; results after 37 years of follow-up.

OBJECTIVES To evaluate respiratory related mortality among underground coal miners after 37 years of follow-up. METHODS Underlying cause of death for 9033 underground coal miners from 31 US mines enrolled between 1969 and 1971 was evaluated with life table analysis. Cox proportional hazards models were fitted to evaluate the exposure-response relationships between cumulative exposure to coal ...

متن کامل

The accuracy of self-reported regulatory data: the case of coal mine dust.

Coal-mine owners are required to measure miner exposures to respirable dust so that compliance with Federal health regulations can be monitored. This study analyzes the problem of possible underreporting of dust exposures. Using two statistical approaches, data for three mining occupations in 54 large underground coal mines during 1976-1978 are examined for evidence of underreporting. First, re...

متن کامل

Improve Drill Dust Collector Capture Through Better Shroud and Inlet Configurations

Overexposure to airborne respirable crystalline silica (or quartz) dust can cause serious or fatal respiratory disease. In particular, some of the most severe cases of silicosis have been observed in surface mine rock drillers. A voluntary lung screening study conducted on surface coal mine workers in Pennsylvania concluded that the incidence rate of silicosis is directly related to age and yea...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005