Rapid MR imaging of articular cartilage with steady-state free precession and multipoint fat-water separation.

نویسندگان

  • Scott B Reeder
  • Norbert J Pelc
  • Marcus T Alley
  • Garry E Gold
چکیده

OBJECTIVE To obtain high-quality high-resolution images of articular cartilage with reduced imaging time, we combined a novel technique of generalized multipoint fat-water separation with three-dimensional (3D) steady-state free precession (SSFP) imaging. SUBJECTS AND METHODS The cartilage of 10 knees in five healthy volunteers was imaged with 3D SSFP imaging and a multipoint fat-water separation method capable of separating fat and water with short TE increments. Fat-saturated 3D spoiled gradient-echo (SPGR) images were obtained for comparison. RESULTS High-quality images of the knee with excellent fat-water separation were obtained with 3D SSFP imaging. Total imaging time required was 58% less than that required for 3D SPGR imaging with a comparable cartilage signal-to-noise ratio and spatial resolution. Unlike 3D SPGR images, 3D SSFP images exhibited bright synovial fluid, providing a potential arthrographic effect. CONCLUSION High-quality high-resolution images of articular cartilage with improved fat-water separation, bright synovial fluid, and markedly reduced acquisition times can be obtained with 3D SSFP imaging combined with a fat-water separation technique.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison the Accuracy of Fetal Brain Extraction from T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (HASTE) MR Image with T2-True Fast Imaging with Steady State Free Precession (TRUFI) MR Image by Level Set Algorithm

Background Access to appropriate images of fetal brain can greatly assist to diagnose of probable abnormalities. The aim of this study was to compare the suitability of T2-True Fast Imaging with Steady State Free Precession (T2-TRUFI), and T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (T2- HASTE( magnetic resonance imaging (MRI) to extract the fetal brain using the level set algorithm...

متن کامل

Fat-suppressed steady-state free precession imaging using phase detection.

Fully refocused steady-state free precession (SSFP) is a rapid, efficient imaging sequence that can provide diagnostically useful image contrast. In SSFP, the signal is refocused midway between excitation pulses, much like in a spin-echo experiment. However, in SSFP, the phase of the refocused spins alternates for each resonant frequency interval equal to the reciprocal of the sequence repetiti...

متن کامل

Rapid phase-modulated water excitation steady-state free precession for fat suppressed cine cardiovascular MR

BACKGROUND The purpose of this article is to describe a steady-state free precession (SSFP) sequence for fat suppressed cine cardiovascular magnetic resonance (CMR). A rapid phase-modulated binomial water excitation (WE) pulse is utilized to minimize repetition time and acquisition time. METHODS Three different water-excitation pulses were combined with cine-SSFP for evaluation. The frequency...

متن کامل

Spectrally selective imaging with wideband balanced steady-state free precession MRI.

PURPOSE Unwanted, bright fat signals in balanced steady-state free precession sequences are commonly suppressed using spectral shaping. Here, a new spectral-shaping method is proposed to significantly improve the uniformity of stopband suppression without compromising the level of passband signals. METHODS The proposed method combines binomial-pattern excitation pulses with a wideband balance...

متن کامل

Multiecho IDEAL gradient-echo water-fat separation for rapid assessment of cartilage volume at 1.5 T: initial experience.

Institutional review board approval and informed consent were obtained for this HIPAA-compliant study. The purpose was to prospectively compare multiecho iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL) gradient-echo (GRE) magnetic resonance (MR) imaging with three-dimensional fat-suppressed (FS) spoiled GRE (SPGR) MR imaging to evaluate the arti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • AJR. American journal of roentgenology

دوره 180 2  شماره 

صفحات  -

تاریخ انتشار 2003