Active surveillance of Methicillin-resistant Staphylococcus aureus in an emergency department: Comparing BD MAX StaphSR kit with the routine MRSA identification method

نویسندگان

  • Poul Kjældgaard
  • Christian B Morgensen
  • Lilli Ø Skov
  • Ming Chen
چکیده

Methods Prospective observational study performed at the ED. Nasal and throat swab specimens from all patients > 10 years who were admitted to the ED from 01.09.2013 to 30.11.2013, were examined. The swabs were, immediately after sampling, incubated in 6% NaCl broth for at least 16 hours and further cultivated on MRSA-chromeand Columbia-agar. 150 ml of the incubated broth was used as sample material for StaphSR.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance of BD Max StaphSR for Screening of Methicillin-Resistant Staphylococcus aureus Isolates among a Contemporary and Diverse Collection from 146 Institutions Located in Nine U.S. Census Regions: Prevalence of mecA Dropout Mutants.

This study determined the performance of BD Max StaphSR and the rate of methicillin-resistant Staphylococcus aureus (MRSA) with an unrecognized staphylococcal cassette chromosome mec (SCCmec) right-extremity junction (MREJ) region among 907 methicillin-resistant S. aureus (MRSA) and 900 methicillin-susceptible S. aureus (MSSA) isolates. The rate of mecA/mecC dropout mutants was also evaluated. ...

متن کامل

Evaluation of the BD Max StaphSR Assay for Detecting Methicillin-Resistant Staphylococcus aureus (MRSA) and Methicillin-Susceptible S. aureus (MSSA) in ESwab-Collected Wound Samples

Staphylococcus aureus is the most common pathogen involved in skin and soft tissue infections, and it is the principal cause of surgical site infections (1–3). Most of the laboratory methods for detecting S. aureus and methicillin-resistant S. aureus (MRSA) from wounds require incubation time and do not support rapid decisions for selection of the most appropriate procedural or therapeutic inte...

متن کامل

Evaluation of the BD GeneOhm StaphSR assay for detection of methicillin-resistant and methicillin-susceptible Staphylococcus aureus isolates from spiked positive blood culture bottles.

To improve the clinical outcome of Staphylococcus aureus septicemia, the early selection of appropriate antibiotic treatment is crucial. Molecular diagnostics represents an attractive approach for the rapid identification of S. aureus and the determination of its methicillin (meticillin) resistance. In direct comparison to other molecular assays (sa442 and mecA real-time PCRs) and standard labo...

متن کامل

Evaluation of BD Max StaphSR and BD Max MRSAXT Assays Using ESwab-Collected Specimens.

The BD Max MRSAXT and the BD Max StaphSR assays were validated for the detection of methicillin-resistant Staphylococcus aureus (MRSA) in ESwab samples. In addition, the BD Max StaphSR assay was evaluated for its ability to detect and differentiate S. aureus and MRSA in the same sample. A total of 255 ESwab samples collected from the anterior nares of patients were tested by each of three BD Ma...

متن کامل

Comparison of BD Max StaphSR and BD Max MRSAXT for Screening of Staphylococcus aureus Clinical Isolates Collected from Hospitals in the United States.

We recently reported the performance of the BD Max StaphSR assay for screening of methicillin-resistant Staphylococcus aureus (MRSA), as well as the prevalence in the U.S. of S. aureus carrying a staphylococcal cassette chromosome (SCCmec) element lacking mecA (so-called dropout mutant) (1). This assay targets the nuc and mecA/C genes and 11 sequences of the SCCmec-orfX right-extremity junction...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 23  شماره 

صفحات  -

تاریخ انتشار 2015