Beam deviation errors in ellipsometric measurements; an analysis.

نویسندگان

  • J R Zeidler
  • R B Kohles
  • N M Bashara
چکیده

The types of error produced by beam deviation in the optical elements of an ellipsometer are examined. It is shown that there are two types of error that may be significant-systematic errors due to a variation in the plane of incidence and in the angle of incidence at the specimen and errors due to the combined effects of beam displacement and nonuniformities in either the detector response or the optical properties of the specimen, the compensator, the polarizer, the analyzer, or the specimen cell. Analytic expressions for the variation in the plane of incidence and in the angle of incidence are given in terms of parameters that can be determined experimentally. A method by which these parameters can be measured is described. It is shown that the azimuthal variation in the angle of incidence produces fundamental errors in conventional zone averaging techniques because the values of psi and Delta are averaged at different angles of incidence in different zones. Methods of experimentally predetermining when such errors are likely to be significant are discussed, and a procedure that cancels most systematic errors due to beam deviation in each zone is described. The combined effects of beam deviation in the polarizer, the compensator, the cell windows, and the analyzer are considered in several commonly used configurations, and the configurations that minimize beam deviation errors are described.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sensitivity of the Ellipsometric Parameters to Angle-of-Incidence Variations.

Formulas by which the partial derivatives of the ellipsometric parameters psi and Delta with respect to the angle of incidence can be calculated are presented. These derivatives are plotted as a function of the angle of incidence, the refractive indices of the film, the substrate, and the immersion medium, and also as a function of film thickness on three-dimensional graphs. These graphs illust...

متن کامل

Fast ellipsometric measurements based on a single crystal photo-elastic modulator.

For quality control in high volume manufacturing of thin layers and for tracking of physical and chemical processes, ellipsometry is a common measurement technology. For such kinds of applications we present a novel approach of fast ellipsometric measurements. Instead of a conventional setup that uses a standard photo-elastic modulator, we use a 92 kHz Single Crystal Photo-Elastic Modulator (SC...

متن کامل

Quantitative measurements for entrance and exit radiation dose confirmation for cancer patients: An analysis of large cohort of patients

Background: The success of radiation therapy depends on accurate dose delivery to the target. Diode in vivo measurement of entrance and exit dose is a valuable quality assurance (QA) tool to ensure accurate dose delivery.  Materials and Methods: This study was performed at BINO Cancer Hospital, Bahawalpur. Entrance and exit dose measurements were done with p-type diode for various types of canc...

متن کامل

Medium-Term Stability of the Photon Beam Energy of An Elekta CompactTM Linear Accelerator Based on Daily Measurements of Beam Quality Factor

Introduction In this study, we aimed to assess the medium-term energy stability of a 6MV Elekta CompactTM linear accelerator. To the best of our knowledge, this is the first published article to evaluate this linear accelerator in terms of energy stability. As well as investigating the stability of the linear accelerator energy over a period of several weeks, the results will be useful for esti...

متن کامل

Accuracy of robotic patient positioners used in ion beam therapy

BACKGROUND In this study we investigate the accuracy of industrial six axes robots employed for patient positioning at the Heidelberg Ion Beam Therapy Center. METHODS In total 1018 patient setups were monitored with a laser tracker and subsequently analyzed. The measurements were performed in the two rooms with a fixed horizontal beam line. Both, the 3d translational errors and the rotational...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Applied optics

دوره 13 8  شماره 

صفحات  -

تاریخ انتشار 1974