Helium-oxygen mixture does not improve gas exchange in mechanically ventilated children with bronchiolitis

نویسندگان

  • Matthew F Gross
  • Robert M Spear
  • Bradley M Peterson
چکیده

STATEMENT OF FINDINGS: Varying concentrations of helium-oxygen (heliox) mixtures were evaluated in mechanically ventilated children with bronchiolitis. We hypothesized that, with an increase in the helium:oxygen ratio, and therefore a decrease in gas density, ventilation and oxygenation would improve in children with bronchiolitis. Ten patients, aged 1-9 months, were mechanically ventilated in synchronized intermittent mandatory ventilation (SIMV) mode with the following gas mixtures delivered at 15-min intervals: 50%/50% nitrogen/oxygen, 50%/50% heliox, 60%/40% heliox, 70%/30% heliox, and return to 50%/50% nitrogen/oxygen. The use of different heliox mixtures compared with 50%/50% nitrogen/oxygen in mechanically ventilated children with bronchiolitis did not result in a significant or noticeable decrease in ventilation or oxygenation.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Extremely low flow tracheal gas insufflation of helium-oxygen mixture improves gas exchange in a rabbit model of piston-type high-frequency oscillatory ventilation

OBJECTIVE The purpose of this study was to show the effects of the tracheal gas insufflation (TGI) technique on gas exchange using helium-oxygen mixtures during high-frequency oscillatory ventilation (HFOV). We hypothesized that a helium-oxygen mixture delivered into the trachea using the TGI technique (0.3 L/min) would enhance gas exchange during HFOV. METHODS Three rabbits were prepared and...

متن کامل

Helium-oxygen mixtures in intubated patients with status asthmaticus and respiratory acidosis.

Seven patients with status asthmaticus intubated for respiratory failure who had elevated airway pressures and persistent respiratory acidosis were successfully ventilated using a mixture of 60 percent helium and 40 percent oxygen. All patients experienced a rapid reduction in airway pressures, CO2 retention, and resolution of acidosis while breathing a helium-oxygen mixture. There were no unto...

متن کامل

Mechanical ventilation with heliox in an animal model of acute respiratory distress syndrome

BACKGROUND Heliox has a lower density and higher diffusion capacity compared to oxygen-in-air. We hypothesized that heliox ventilation allows for a reduction in minute volume ventilation and inspiratory pressures needed for adequate gas exchange in an animal model of an acute lung injury. METHODS After intratracheal instillation of lipopolysaccharide (10 mg/kg), adult rats were randomized to ...

متن کامل

Effects of heliox as carrier gas on ventilation and oxygenation in an animal model of piston-type HFOV: a crossover experimental study

OBJECTIVE This study aimed to compare gas exchange with heliox and oxygen-enriched air during piston-type high-frequency oscillatory ventilation (HFOV). We hypothesized that helium gas would improve both carbon dioxide elimination and arterial oxygenation during piston-type HFOV. METHOD Five rabbits were prepared and ventilated by piston-type HFOV with carrier 50% helium/oxygen (heliox50) or ...

متن کامل

Helium-oxygen mixture to facilitate ventilation in patients with bronchiolitis obliterans syndrome after lung transplantation.

A combination of helium and oxygen (heliox) can facilitate gas exchange and limit peak inspiratory pressures through reduced resistance to gas flow and decreased turbulent flow. The combination of these gases has been used for a variety of upper and lower airway conditions, including patients who were spontaneously breathing, receiving noninvasive ventilation, as well as during mechanical venti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Critical Care

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2000