Shape based Monte Carlo code for light transport in complex heterogeneous Tissues.
نویسندگان
چکیده
A Monte Carlo code for the calculation of light transport in heterogeneous scattering media is presented together with its validation. Triangle meshes are used to define the interfaces between different materials, in contrast with techniques based on individual volume elements. This approach allows to address realistic problems in a flexible way. A hierarchical spatial organisation enables a fast photon-surface intersection test. The application of the new environment to evaluate the impact of the trabecular structure of bone on its optical properties is demonstrated. A model of the trabecular micro structure recovered from microCT data was used to compute light distribution within tissue. Time-resolved curves across a spherical bone volume were computed. The work presented enables simulation of radiative transport in complex reality-based models of tissue and serves as a powerful, generic tool to study the effect of heterogeneity in the field of biomedical optics.
منابع مشابه
Application of MCNP4C Monte Carlo code in radiation dosimetry in heterogeneous phantom
Background: In treating patients with radiation, the degree of accuracy for the delivery of tumor dose is recommended to be within ± 5% by ICRU in report 24. The experimental studies have shown that the presence of low-density inhomogeneity in areas such as the lung can lead to a greater than 30% change in the water dose data. Therefore, inhomogeneity corrections should be used in treatment pla...
متن کاملEvaluation of Lung Dose in Esophageal Cancer Radiotherapy Using Monte Carlo Simulation
Background and purpose: Radiation therapy make an important contribution in the control and treatment of cancers. Lungs are the main organs at risk in esophageal cancer radiotherapy. Difference between the dose distribution due to the treatment planning system (TPS) and the patient's body dose is dependent on the calculation of the treatment planning system algorithm, which is more pronounced i...
متن کاملDesign of Light Multi-layered Shields for Use in Diagnostic Radiology and Nuclear Medicine via MCNP5 Monte Carlo Code
Introduction Lead-based shields are the most widely used attenuators in X-ray and gamma ray fields. The heavy weight, toxicity and corrosion of lead have led researchers towards the development of non-lead shields. Materials and Methods The purpose of this study was to design multi-layered shields for protection against X-rays and gamma rays in diagnostic radiology and nuclear medicine. In this...
متن کاملGPU-based Monte Carlo simulation for light propagation in complex heterogeneous tissues.
As the most accurate model for simulating light propagation in heterogeneous tissues, Monte Carlo (MC) method has been widely used in the field of optical molecular imaging. However, MC method is time-consuming due to the calculations of a large number of photons propagation in tissues. The structural complexity of the heterogeneous tissues further increases the computational time. In this pape...
متن کاملComparison of ScintSim1 and Geant4 Monte Carlo simulation codes for optical photon transport in thick segmented scintillator arrays
Introduction: Arrays of segmented scintillation crystals are useful in megavoltage x-ray imaging detectors for image-guided radiotherapy. Most previous theoretical studies on these detectors have modelled only ionizing-radiation transport. Scintillation light also affects detector performance. ScintSim1, our previously reported optical Monte Carlo code for such detector...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Optics express
دوره 15 21 شماره
صفحات -
تاریخ انتشار 2007