Speckle reduction of retinal optical coherence tomography based on contourlet shrinkage.

نویسندگان

  • Jianbing Xu
  • Haiyan Ou
  • Edmund Y Lam
  • P C Chui
  • Kenneth K Y Wong
چکیده

Speckle reduction of retinal optical coherence tomography (OCT) images helps the diagnosis of ocular diseases. In this Letter, we present a speckle reduction method based on shrinkage in the contourlet domain for retinal OCT images. The algorithm overcomes the disadvantages of the wavelet shrinkage method, which lacks directionality and anisotropy. The trade-off between speckle reduction and edge preservation is controlled by a single adjustable parameter, which determines the threshold in the contourlet domain. Results show substantial reduction of speckle noise and enhanced visualization of layer structures as demonstrated in the image of the central fovea region of the human retina. It is expected to be utilized in a wide range of biomedical imaging applications.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Speckle Noise Reduction for the Enhancement of Retinal Layers in Optical Coherence Tomography Images

Introduction One of the most important pre-processing steps in optical coherence tomography (OCT) is reducing speckle noise, resulting from multiple scattering of tissues, which degrades the quality of OCT images. Materials and Methods The present study focused on speckle noise reduction and edge detection techniques. Statistical filters with different masks and noise variances were applied on ...

متن کامل

The Application of Multi-Layer Artificial Neural Networks in Speckle Reduction (Methodology)

Optical Coherence Tomography (OCT) uses the spatial and temporal coherence properties of optical waves backscattered from a tissue sample to form an image. An inherent characteristic of coherent imaging is the presence of speckle noise. In this study we use a new ensemble framework which is a combination of several Multi-Layer Perceptron (MLP) neural networks to denoise OCT images. The noise is...

متن کامل

Bayesian-Based Speckle Suppression for SAR Image Using Contourlet Transform

⎯A novel and efficient speckle noise reduction algorithm based on Bayesian contourlet shrinkage using contourlet transform is proposed. First, we show the sub-band decompositions of SAR images using contourlet transforms, which provides sparse representation at both spatial and directional resolutions. Then, a Bayesian contourlet shrinkage factor is applied to the decomposed data to estimate th...

متن کامل

Speckle reduction in optical coherence tomography images based on wave atoms.

Optical coherence tomography (OCT) is an emerging noninvasive imaging technique, which is based on low-coherence interferometry. OCT images suffer from speckle noise, which reduces image contrast. A shrinkage filter based on wave atoms transform is proposed for speckle reduction in OCT images. Wave atoms transform is a new multiscale geometric analysis tool that offers sparser expansion and bet...

متن کامل

Evaluation of Optical Coherence Tomography Angiography Findings in Patients with Branch Retinal Vein Occlusion

Purpose: To analyze the correlation of optical coherence tomography angiography (OCTA) findings with visual acuity (VA) in patients with branch retinal vein occlusion (BRVO). Methods: This cross-sectional study was performed on 20 eyes of 20 patients with unilateral BRVO involving the macula referred to the ophthalmology clinic of Rassoul Akram Hospital. OCTA imaging was conducted for all patie...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Optics letters

دوره 38 15  شماره 

صفحات  -

تاریخ انتشار 2013