Evaluation of infant membrane oxygenator in sheep.

نویسندگان

  • Renata Geron Finoti
  • Domingo Marcolino Braile
  • Ulisses Alexandre Croti
  • Marcos Aurélio Barboza de Oliveira
  • Moacir Fernandes de Godoy
  • João Carlos Ferreira Leal
  • Sebastião Rodrigues Policarpo
  • Marden Leonardi Lopes
چکیده

OBJECTIVE To analyze the security and efficacy of a new membrane oxygenator, the so-called OXM - 1500. METHODS From May 2005 to September 2006, six sheep of Santa Inês breed (five male and one female, respectively) were studied. The average body weight was 14.1 (+/-5) kg, body surface 0.6 (+/-0.2) m(2) and a mean age 3.8 (+/-1.5) months. All of them were submitted to extracorporeal circulation (CEC) with evaluation at 10, 30, 60, 120, 180 and 240 minutes. The following values were obtained: values of oxygen transference (TTO2) and carbon dioxide transference (TTCO2), haemoglobin (HBS) and free haemoglobin (HBL), the score of platelets and of leucocytes, and heat transference rate. RESULTS TTO2 and TTCO2 were adequate. Lesion of the majority formed blood elements was insignificant; there no modifications in HBS, HBL levels; platelets and leucocytes decreased over time. Heat exchange was effective (p < 0.05). CONCLUSIONS The membrane OXM--1500 infant oxygenator, tested in sheep, showed adequate oxygenation capacity, CO2 removal capacity, and small alteration of haemoglobin and platelets without significant decrease of leucocytes, as expected. Heat exchanger connected to the oxygenator was efficient in temperature changes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In-Vitro Evaluation of Two Types of Neonatal Oxygenators in Handling Gaseous Microemboli and Maintaining Optimal Hemodynamic Stability During Cardiopulmonary Bypass

Objective Usually only FDA-approved oxygenators are subject of studies by the international scientific community. The objective of this study is to evaluate two types of neonatal membrane oxygenators in terms of transmembrane pressure gradient, hemodynamic energy transmission and gaseous microemboli capture in simulated cardiopulmonary bypass systems. Methods We investigated the Braile Infant...

متن کامل

Retrospective analysis comparing hollow fiber and silicone membrane oxygenators for neonates on ECMO.

There is little information showing the use of microporous polypropylene hollow fiber oxygenators during extra-corporeal life support (ECLS). Recent surveys have shown increasing use of these hollow fibers amongst ECLS centers in the United States. We performed a retrospective analysis comparing the Terumo BabyRx hollow fiber oxygenator to the Medtronic 800 silicone membrane oxygenator on 14 ne...

متن کامل

A description of a prototype miniature extracorporeal membrane oxygenation circuit using current technologies in a sheep model.

In the United States, standardization of neonatal extracorporeal membrane oxygenation (ECMO) circuit was achieved during the 1980s. Since that time, the consoles and components of the ECMO circuit have remained fundamentally unchanged (bladder, rollerpump, silicone membrane oxygenator). Extracorporeal technology, however, has witnessed many significant advancements in components during the past...

متن کامل

An in vitro protocol for evaluation and comparison of membrane oxygenators.

With the trend in open heart surgery toward normothermic bypass and warm blood cardioplegia, greater demand is being placed on the perfusionist to select an oxygenator that will perform safely and efficiently under a variety of conditions. While manufacturers report performance parameters for their products, the data is often not comparable due to widely differing conditions. Recent in vitro ...

متن کامل

Evaluation of Quadrox-i adult hollow fiber oxygenator with integrated arterial filter.

Gaseous microemboli (GME) remain a challenge for cardiopulmonary bypass procedures in adult as well as pediatric cardiac surgery patients. The present study tested the effectiveness of a new adult membrane oxygenator in models both with and without an integrated arterial filter to evaluate GME trapping capability and determine membrane pressure drops at various flow rates and temperatures. The ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Revista brasileira de cirurgia cardiovascular : orgao oficial da Sociedade Brasileira de Cirurgia Cardiovascular

دوره 23 3  شماره 

صفحات  -

تاریخ انتشار 2008