Improved imaging of cochlear nerve hypoplasia using a 3-Tesla variable flip-angle turbo spin-echo sequence and a 7-cm surface coil.
نویسندگان
چکیده
OBJECTIVE/HYPOTHESIS Magnetic resonance imaging of the temporal bone has an important role in decision making with regard to cochlea implantation, especially in children with cochlear nerve deficiency. The purpose of this study was to evaluate the usefulness of the combination of an advanced high-resolution T2-weighted sequence with a surface coil in a 3-Tesla magnetic resonance imaging scanner in cases of suspected cochlear nerve aplasia. STUDY DESIGN Prospective study. METHODS Seven patients with cochlear nerve hypoplasia or aplasia were prospectively examined using a high-resolution three-dimensional variable flip-angle turbo spin-echo sequence using a surface coil, and the images were compared with the same sequence in standard resolution using a standard head coil. Three neuroradiologists evaluated the magnetic resonance images independently, rating the visibility of the nerves in diagnosing hypoplasia or aplasia. RESULTS Eight ears in seven patients with hypoplasia or aplasia of the cochlear nerve were examined. The average age was 2.7 years (range, 9 months-5 years). Seven ears had accompanying malformations. The inter-rater reliability in diagnosing hypoplasia or aplasia was greater using the high-resolution three-dimensional variable flip-angle turbo spin-echo sequence (fixed-marginal kappa: 0.64) than with the same sequence in lower resolution (fixed-marginal kappa: 0.06). CONCLUSIONS Examining cases of suspected cochlear nerve aplasia using the high-resolution three-dimensional variable flip-angle turbo spin-echo sequence in combination with a surface coil shows significant improvement over standard methods.
منابع مشابه
Assessment of the Characteristics of MRI Coils in Terms of RF Non-Homogeneity Using Routine Spin Echo Sequences
Introduction: One of the major causes of image non-uniformity in MRI is due to the existence of non-homogeneity in RF receive and transmit. This can be the most effective source of error in quantitative studies in MRI imaging. Part of this non-homogeneity demonstrates the characteristics of RF coil and part of it is due to the interaction of RF field with the material being imaged...
متن کاملاندازه گیری غیریکنواختی امواج رادیوئی در ام آر آی
Introduction: Non-uniformity is one of the most important parameters affecting MRI images which can lead to harmful effects in the diagnosis and analysis of qualitative and quantitative methods. The present study introduced a method for measuring RF non-homogeneity in MRI systems. Methods and Materials: To verify the uniformity of B0 and B1 fields, a cylindrical phantom with a diameter of 24 c...
متن کاملWhole-Brain FLAIR using 3D TSE with Variable Flip Angle Readouts Optimized for 7 Tesla
Introduction Whole-brain FLAIR is a requirement for most routine clinical neuroimaging. Traditional techniques employ a two-dimensional inversion-recovery turbo spin echo (2D IR-TSE) pulse sequence with the inversion time (TI) chosen to null CSF signal. However, at 7 Tesla (T) and higher whole-brain FLAIR using traditional techniques has not been feasible in an acceptable scan time. The traditi...
متن کاملImproving T2 -weighted imaging at high field through the use of kT -points.
PURPOSE At high magnetic field strengths (B(0) ≥ 3 T), the shorter radiofrequency wavelength produces an inhomogeneous distribution of the transmit magnetic field. This can lead to variable contrast across the brain which is particularly pronounced in T(2) -weighted imaging that requires multiple radiofrequency pulses. To obtain T(2) -weighted images with uniform contrast throughout the whole b...
متن کاملParallel-transmission-enabled 3D T2-weighted imaging of the human brain at 7 Tesla
Purpose: At ultra-high magnetic field, B1 + and ΔB0 non-uniformities cause undesired contrast and signal inhomogeneities. Tailored radiofrequency (RF) pulses exploiting parallel transmission (pTX) have already demonstrated their ability to mitigate these phenomena, especially in the framework of T1-weighted imaging . Yet the design of refocusing pulses employed in T2-weighted imaging remains ch...