Time-averaged fluorescence intensity analysis in fluorescence fluctuation polarization sensitive experiments

نویسندگان

  • Lior Turgeman
  • Dror Fixler
چکیده

In fluorescence fluctuation polarization sensitive experiments, the limitations associated with detecting the rotational timescale are usually eliminated by applying fluorescence correlation spectroscopy analysis. In this paper, the variance of the time-averaged fluorescence intensity extracted from the second moment of the measured fluorescence intensity is analyzed in the short time limit, before fluctuations resulting from rotational diffusion average out. Since rotational correlation times of fluorescence molecules are typically much lower than the temporal resolution of the system, independently of the time bins used, averaging over an ensemble of time-averaged trajectories was performed in order to construct the time-averaged intensity distribution, thus improving the signal-to-noise ratio. Rotational correlation times of fluorescein molecules in different viscosities of the medium within the range of the anti-bunching time (1-10 ns) were then extracted using this method.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fluorescence-based transient state monitoring for biomolecular spectroscopy and imaging.

To increase read-out speed, sensitivity or specificity, an often applied strategy in fluorescence-based biomolecular spectroscopy and imaging is to simultaneously record two or more of the fluorescence parameters: intensity, lifetime, polarization or wavelength. This review highlights how additional, to-date largely unexploited, information can be extracted by monitoring long-lived, photo-induc...

متن کامل

Probing single-molecule dynamics photon by photon

We present the theoretical rationales for data analysis protocols that afford an efficient extraction of conformational dynamics on a broad range of time scales from single-molecule fluorescence lifetime trajectories. Based on correlation analyses, a photon-by-photon approach on one hand provides the highest time resolution, whereas a minimal-binning method on the other hand is most suitable fo...

متن کامل

Time-integrated fluorescence cumulant analysis in fluorescence fluctuation spectroscopy.

We introduce a new analysis technique for fluorescence fluctuation data. Time-integrated fluorescence cumulant analysis (TIFCA) extracts information from the cumulants of the integrated fluorescence intensity. TIFCA builds on our earlier FCA theory, but in contrast to FCA or photon counting histogram (PCH) analysis is valid for arbitrary sampling times. The motivation for long sampling times li...

متن کامل

Comparison of different fluorescence fluctuation methods for their use in FRET assays: monitoring a protease reaction.

We compare the accuracy of a variety of Fluorescence Fluctuation Spectroscopy (FFS) methods for the study of Förster Resonance Energy Transfer (FRET) assays. As an example, the cleavage of a doubly labeled, FRET-active peptide substrate by the protease Trypsin is monitored and analyzed using methods based on fluorescence intensity, Fluorescence Correlation Spectroscopy (FCS) and Fluorescence In...

متن کامل

Phase fluctuation in phospholipid membranes revealed by Laurdan fluorescence.

The organization of lipids surrounding membrane proteins can influence their properties. We have used 6-dodecanoyl-2-dimethylaminonaphthalene (Laurdan) to study phase coexistence and phase interconversion in membrane model systems. The fluorescence properties of Laurdan provide a unique possibility to study lipid domains because of the different excitation and emission spectra of this probe in ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2013