What covariance mechanisms underlie green/red equiluminance, luminance contrast sensitivity and chromatic (green/red) contrast sensitivity?

نویسندگان

  • Karen R. Dobkins
  • Karen L. Gunther
  • David H. Peterzell
چکیده

In order to investigate the mechanisms underlying green/red equiluminance matches in human observers and their relationship to mechanisms subserving luminance and/or chromatic (green/red) contrast sensitivity, we tested 21 human subjects along these dimensions at 16 different spatial and temporal frequencies (spatial frequency, 0.25-2 c/deg; temporal frequency, 2-16 Hz) and applied factor analysis to extract mechanisms underlying the data set. The results from our factor analysis revealed separate sources of variability for green/red equiluminance, luminance sensitivity and chromatic sensitivity, thus suggesting separate mechanisms underlying each of the three main conditions. When factor analysis was applied separately to green/red equiluminance data, two temporally-tuned factors were revealed (factor 1, 2-4 Hz; factor 2, 8-16 Hz), suggesting the existence of separate mechanisms underlying equiluminance settings at low versus high temporal frequencies. In addition, although the three main conditions remained separate in our factor analysis of the entire data set, our correlation matrix nonetheless revealed systematic correlations between equiluminance settings and luminance sensitivity at high temporal frequencies, and between equiluminance settings and chromatic sensitivity at low temporal frequencies. Taken together, these data suggest that the high temporal frequency factor underlying green/red equiluminance is governed predominantly by luminance mechanisms, while the low temporal frequency factor receives contribution from chromatic mechanisms.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Individual differences in chromatic (red/green) contrast sensitivity are constrained by the relative number of L- versus M-cones in the eye

Many previous studies have shown that the relative number of long-wavelength-selective (L) versus medium-wavelength-selective (M) cones in the eye influences spectral sensitivity revealed perceptually. Here, we hypothesize that the L:M cone ratio should also influence red/green chromatic contrast sensitivity. To test this, in each subject we derived an estimate of L:M ratio based on her red/gre...

متن کامل

Spatial frequency tuned covariance channels for red–green and luminance-modulated gratings: psychophysical data from human infants

This study concerns the spatial-frequency-tuned channels underlying infants' contrast sensitivity functions (CSFs) for red-green chromatic stimuli, and their relationship to the channels underlying infants' CSFs for luminance-modulated stimuli. Behavioral (forced-choice preferential-looking) techniques and stationary stimuli were used. In experiment 1. contrast thresholds were measured in 4- an...

متن کامل

Modelling spatial contrast sensitivity functions for chromatic and luminance-modulated gratings

We extended our detection model of achromatic spatial vision (Rovamo, J., Mustonen, J., & Näsänen, R. (1994a). Modelling contrast sensitivity as a function of retinal illuminance and grating area. Vision Research, 34, 1301-1314) to colour vision by taking into account the fact that due to the spatio-chromatic opponency of retinal ganglion cells and dorsal lateral geniculate nucleus (dLGN) neuro...

متن کامل

Spatial frequency tuned covariance channels for red–green and luminance-modulated gratings: psychophysical data from human adults

Both chromatic and luminance-modulated stimuli are served by multiple spatial-frequency-tuned channels. This experiment investigated the independence versus interdependence of spatial frequency channels that serve the detection of red-green chromatic versus yellow-black luminance-modulated stimuli at low spatial frequencies. Contrast thresholds for both chromatic and luminance-modulated grating...

متن کامل

Sensitivity of macaque retinal ganglion cells to chromatic and luminance flicker.

1. We have studied the sensitivity of macaque retinal ganglion cells to sinusoidal flicker. Contrast thresholds were compared for stimuli which alternated only in luminance ('luminance flicker') or chromaticity ('chromatic flicker'), or which modulated only the middle- or long-wavelength-sensitive cones ('silent substitution'). 2. For luminance flicker, the lowest thresholds were those of phasi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Vision Research

دوره 40  شماره 

صفحات  -

تاریخ انتشار 2000