Particle sizing in strongly turbid suspensions with the one-beam cross-correlation dynamic light-scattering technique.
نویسندگان
چکیده
The utility of the one-beam cross-correlation dynamic light-scattering system for sizing small particles in suspension was previously limited by its small-intensity signal-to-baseline ratio for strongly turbid suspensions. We describe three improvements in the optical system and sample cell that raise the ratio to a value comparable with that of other cross-correlation dynamic light-scattering systems. These improvements are (i) using a square cross-sectional sample cell to minimize the attenuation of the incident beam and singly scattered light, (ii) placing a 200-microm-wide slit between the sample cell and the detector fibers to mask off the region of weak single scattering and strong multiple scattering from the detectors' field of view, and (iii) aligning the center of the detectors' field of view with the region of strongest single scattering. We analyze a number of suspensions of polystyrene latex spheres with a diameter between 65 and 562 nm in water using this improved one-beam instrument and find that the measured radius is determined in a 2-min data collection time to better than +/-10% for volume fractions of the suspended polystyrene latex spheres up to a few percent.
منابع مشابه
Experimental suppression of multiple scattering : E†ect on dynamic and static scattering data
Combination of dynamic and static light scattering experiments gives important information on structural and dynamic properties of polymer solutions and colloidal suspensions. However, the analysis of light scattering experiments in turbid media is highly complicated due to the presence of multiple scattering. Recently, a one-beam set-up has been proposed and it could be shown that the cross co...
متن کاملModulated 3D cross-correlation light scattering: improving turbid sample characterization.
Accurate characterization using static light scattering (SLS) and dynamic light scattering (DLS) methods mandates the measurement and analysis of singly scattered light. In turbid samples, the suppression of multiple scattering is therefore required to obtain meaningful results. One powerful technique for achieving this, known as 3D cross-correlation, uses two simultaneous light scattering expe...
متن کاملA new instrument for time-resolved static and dynamic light-scattering experiments in turbid media.
We present a new 3D cross-correlation instrument that not only allows for static and dynamic scattering experiments with turbid samples but measures at four angles simultaneously. It thus extends the application of cross-correlation light scattering to time-resolved studies where we can, for example, efficiently investigate the temporal evolution of aggregating or phase separating turbid disper...
متن کاملMultiple-scattering suppression in dynamic light scattering based on a digital camera detection scheme.
We introduce a charge-coupled device (CCD) camera-based detection scheme in dynamic light scattering that provides information on the single-scattered autocorrelation function even for fairly turbid samples. It is based on the single focused laser beam geometry combined with the selective cross-correlation analysis of the scattered light intensity. Using a CCD camera as a multispeckle detector,...
متن کاملDevelopment of a standard method for nanoparticle sizing by using the angular dependence of dynamic light scattering.
A standard method for nanoparticle sizing based on the angular dependence of dynamic light scattering was developed. The dependences of the diffusion coefficients for aqueous suspensions of polystyrene latex on the concentration and scattering angle were accurately measured by using a high-resolution dynamic light-scattering instrument. Precise measurements of the short-time correlation functio...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Applied optics
دوره 38 15 شماره
صفحات -
تاریخ انتشار 1999