Image registration accuracy of a 3-dimensional transrectal ultrasound-guided prostate biopsy system.

نویسندگان

  • Yujun Guo
  • Priya N Werahera
  • Ramkrishnan Narayanan
  • Lu Li
  • Dinesh Kumar
  • E David Crawford
  • Jasjit S Suri
چکیده

OBJECTIVE For a follow-up prostate biopsy procedure, it is useful to know the previous biopsy locations in anatomic relation to the current transrectal ultrasound (TRUS) scan. The goal of this study was to validate the performance of a 3-dimensional TRUS-guided prostate biopsy system that can accurately relocate previous biopsy sites. METHODS To correlate biopsy locations from a sequence of visits by a patient, the prostate surface data obtained from a previous visit needs to be registered to the follow-up visits. Two interpolation methods, thin-plate spline (TPS) and elastic warping (EW), were tested for registration of the TRUS prostate image to follow-up scans. We validated our biopsy system using a custom-built phantom. Beads were embedded inside the phantom and were located in each TRUS scan. We recorded the locations of the beads before and after pressures were applied to the phantom and then compared them with computer-estimated positions to measure performance. RESULTS In our experiments, before system processing, the mean target registration error (TRE) +/- SD was 6.4 +/- 4.5 mm (range, 3-13 mm). After registration and TPS interpolation, the TRE was 5.0 +/- 1.03 mm (range, 2-8 mm). After registration and EW interpolation, the TRE was 2.7 +/- 0.99 mm (range, 1-4 mm). Elastic warping was significantly better than the TPS in most cases (P < .0011). For clinical applications, EW can be implemented on a graphics processing unit with an execution time of less than 2.5 seconds. CONCLUSIONS Elastic warping interpolation yields more accurate results than the TPS for registration of TRUS prostate images. Experimental results indicate potential for clinical application of this method.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A molecular image-directed, 3D ultrasound-guided biopsy system for the prostate

Systematic transrectal ultrasound (TRUS)-guided biopsy is the standard method for a definitive diagnosis of prostate cancer. However, this biopsy approach uses two-dimensional (2D) ultrasound images to guide biopsy and can miss up to 30% of prostate cancers. We are developing a molecular image-directed, three-dimensional (3D) ultrasound image-guided biopsy system for improved detection of prost...

متن کامل

A PET/CT Directed, 3D Ultrasound-Guided Biopsy System for Prostate Cancer

Prostate cancer affects 1 in 6 men in the USA. Systematic transrectal ultrasound (TRUS)-guided biopsy is the standard method for a definitive diagnosis of prostate cancer. However, this "blind" biopsy approach can miss at least 20% of prostate cancers. In this study, we are developing a PET/CT directed, 3D ultrasound image-guided biopsy system for improved detection of prostate cancer. In order...

متن کامل

Closed-Loop Control in Fused MR-TRUS Image-Guided Prostate Biopsy

Multi-modality fusion imaging for targeted prostate biopsy is difficult because of prostate motion during the biopsy procedure. A closed-loop control mechanism is proposed to improve the efficacy and safety of the biopsy procedure, which uses real-time ultrasound and spatial tracking as feedback to adjust the registration between a preoperative 3D image (e.g. MRI) and real-time ultrasound image...

متن کامل

Towards 3D Ultrasound Image Based Soft Tissue Tracking: A Transrectal Ultrasound Prostate Image Alignment System

The emergence of real-time 3D ultrasound (US) makes it possible to consider image-based tracking of subcutaneous soft tissue targets for computer guided diagnosis and therapy. We propose a 3D transrectal US based tracking system for precise prostate biopsy sample localisation. The aim is to improve sample distribution, to enable targeting of unsampled regions for repeated biopsies, and to make ...

متن کامل

Prostate biopsies guided by three-dimensional real-time (4-D) transrectal ultrasonography on a phantom: comparative study versus two-dimensional transrectal ultrasound-guided biopsies

OBJECTIVE This study evaluated the accuracy in localisation and distribution of real-time three-dimensional (4-D) ultrasound-guided biopsies on a prostate phantom. METHODS A prostate phantom was created. A three-dimensional real-time ultrasound system with a 5.9MHz probe was used, making it possible to see several reconstructed orthogonal viewing planes in real time. Fourteen operators perfor...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine

دوره 28 11  شماره 

صفحات  -

تاریخ انتشار 2009